Operator dependent variability in quantitative analysis of myocardial perfusion images.

نویسندگان

  • L Akesson
  • A Svensson
  • L Edenbrandt
چکیده

The purpose of this study was to evaluate variability in the quantification of myocardial perfusion images obtained by a group of experienced operators using two widely used programs. The Cedars Emory quantitative analysis program (CEqual) was used to quantify the size of perfusion defects and the Cedars-Sinai quantitative gated single-photon emission tomography program was used to quantify left ventricular function. Five patients with reversible apical defects, five with fixed apical defects and three patients with normal perfusion were selected. Eight experienced medical laboratory technologists processed the studies from raw projection data. The manual steps consisted of defining two alignment axes parallel to the long axis of the left ventricle, and for the CEqual program selecting apex and base in the short axis slices in the rest and stress studies. Wide variability between the operators in the quantification of reversibility could be seen in all three vascular territories. A range >10% was found in at least one vascular territory for nine of the 13 patients. The differences in left ventricular ejection fraction (LVEF) between operators were <5% for all 13 patients. The large variability in the quantification of reversible apical perfusion defects may influence the clinical interpretation and cause false conclusions. In contrast, inter-operator variability for the quantification of the LVEF was low.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Myocardial perfusion SPECT: Perfusion quantification

Different software tools for quantification of myocardial perfusion SPECT (MPS) studies are routinely used. Several perfusion parameters can be computed automatically.  Interpretation of the MPS should start with visual inspection of the rotating planar images, visual analysis of reconstructed SPECT slices and then quantitative analysis to confirm the visual impression. Quantification should be...

متن کامل

Semi-quantitative segmental perfusion scoring in myocardial perfusion SPECT: visual vs. automated analysis

Introduction: It is recommended that the physician apply at least a semi-quantitative segmental scoring system in myocardial perfusion SPECT.  We aimed to assess the agreement between automated semi-quantitative analysis using QPS (quantitative Perfusion SPECT) software and visual approach for calculation of summed stress  score (SSS), summed rest score (SRS) and summed difference score (SDS). ...

متن کامل

Evaluating the Effect of Injected Dose of 99mTc- MIBI on the Quantitative Parameters of Myocardial Perfusion Imaging

Background: 99mTc-MIBI cardiac perfusion scanning is recognized as a clinically useful method in evaluating coronary artery disease. By the implementation of new imaging techniques and systems, it seems possible to obtain high-quality images with a lower dose of radiopharmaceuticals. The purpose of this study was to evaluate the effect of injection dose of 99mTc-MIBI on quantitative parameters ...

متن کامل

Differential impact of multi-focus fan beam collimation with L-mode and conventional systems on the accuracy of myocardial perfusion imaging: Quantitative evaluation using phantoms

Objective(s): A novel IQ-SPECTTM method has become widely used in clinical studies. The present study compares the quality of myocardial perfusion images (MPI) acquired using the IQ-SPECTTM (IQ-mode),conventional (180° apart: C-mode) and L-mode (90° apart: L-mode) systems. We assessed spatial resolution, image reproducibility and quantifiability using various physical phantoms. Materials and Me...

متن کامل

Performance of myocardial perfusion imaging using multi-focus fan beam collimator with resolution recovery reconstruction in a comparison with conventional SPECT

  Objective: IQSPECT is an advanced high-speed SPECT modality for performing myocardial perfusion imaging (MPI), which uses a multi-focus fan beam collimator with resolution recovery reconstruction. The aim of this study was to compare IQSPECT compared with conventional SPECT interms of performance based on standard clinical protocols. In addition, we examined the concordance between convention...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical physiology and functional imaging

دوره 24 6  شماره 

صفحات  -