Comparison of Synchrotron Radiation Calculation between Egs4, Fluka, Photon and Stac8

نویسندگان

  • Y. Asano
  • J. C. Liu
چکیده

With constructing and operating the third generation facilities such as SPring-8, however, high energy synchrotron radiation of extremely high intense is available, and high accuracy should be required in the shielding and safety design for the beamline of synchrotron radiation. Furthermore, the middle size facilities, such as CLS (Canadian Light Source), are now under construction and the optimum design of shielding is desired strongly to construct the beamline with safety and compact. It is necessary to verify the detailed evaluation technique. Therefore, taking the SPEAR3 ring bending magnet and BL11-3 wiggler beamlines of SSRL as the examples, the characteristics of the synchrotron radiation shielding design codes PHOTON[1] and STAC8[2] were investigated by comparing with Monte Carlo simulation codes EGS4[3],[4] and FLUKA[5].

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of FLUKA and STAC8 for shielding calculations of the hard X-ray line of the LCLS

This Note describes calculations of the shielding necessary to reduce the dose rate to less than 0.05 mrem/h when synchrotron radiations emitted by the LCLS electrons beam hit a worst type scattering target located in the hard X-ray line. The calculations were performed using the FLUKA Monte-Carlo code and as well as the STAC8 analytical code. The photon spectrum used as a source term correspon...

متن کامل

Estimation of Synchrotron Radiation Dose Outside The Hutch of SPring-8 Beamline

INTRODUCTION Synchrotron radiation facilities are to get high brilliance and high power density of synchrotron radiation. Especially, the third generation synchrotron radiation facilities such as the European Synchrotron Radiation Facility (ESRF)(1), The Advanced Photon Source (APS)(2), and SPring-8(3) can get extremely high brilliance, high power density, and high energy photons. The shields o...

متن کامل

Comparison of measured and Monte Carlo calculated dose distributions from “circular collimators” for radiosurgical beams

Background: Stereotactic radiosurgery is an important clinical tool for the treatment of small lesions in the brain, including benign conditions, malignant and localized metastatic tumors. A dosimetry study was performed for Elekta ‘Synergy S ’ as a dedicated Stereotactic radiosurgery unit, capable of generating circular radiation fields with diameters of 1-5 cm at isocentre using the BEAM/EGS4...

متن کامل

GAS BREMStiRAHLUNG AND ASSOCIATED PHOTON-NEUTRON SHIELDING CALCULATIONS FOR ELECTRON STORAGE RINGS bY

The EGS4 electron-photon Monte Carlo code has been used to study the characteristics of the bremsstrahlung x-rays generated from the interaction of circulating electrons with the residual gas in accelerator storage rings. Gas bremsstrahlung dose rates are given for various opening angles as a function of the electron beam energy ranging from 0.510 GeV. Photon and neutron dose rates, generated f...

متن کامل

A Review of the Applications of Synchrotron Radiation in Archaeological Sciences

The scientific research regarding investigation, characterization and protection of the archeological specimens is manifested through a notable participation of multidisciplinary subjects and experts, scientists and archeometrists. One of the main principals which are considered by archaeometrists in the study of the precious specimens is the utilizing nondestructive methods. As an example, in ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2002