Comparison of cephalometric measurements with digital versus conventional cephalometric analysis.
نویسندگان
چکیده
The aim of this study was to evaluate the accuracy and reliability of angular and linear cephalometric measurements using a computerized method of direct digital radiographs. This was then compared with the measurements obtained with a computerized method that uses a digitizing pad and hand tracing of printout radiographs. Pre-treatment digital cephalometric radiographs of 125 patients were traced using Vistadent 2.1 AT and Jiffy Orthodontic Evaluation (JOE) software programs and by hand tracing of the printouts. Twenty-six anatomical landmarks were defined on each radiograph by a single investigator and 28 variables were calculated. Statistical analysis was undertaken using one-way analysis of variance and multiple group comparisons using Duncan's test at a significance level of 0.05. Low correlation coefficients indicated poor reproducibility for nasolabial angle for each of the three methods (P > 0.05). Most of the variables showed consistency between the three methods except for nasolabial angle, ANS-Me, APFH, L1-NB, Nperp-Pg, Go-Me, and U1-NA measurements. The findings indicated that most of the cephalometric measurements were highly reproducible with direct digital radiographs using Vistadent 2.1 AT as well as with printouts using both JOE software and hand tracing. Despite the low correlation for some measurements between the Vistadent 2.1 AT, JOE, and hand-tracing methods, most of the commonly used measurements were accurate. The user-friendly and time-saving nature of the computerized method using digital radiographs makes it the preferred option.
منابع مشابه
Accuracy of Linear Cephalometric Measurements with Scanned Lateral Cephalograms
Digital Cephalometry needs to be as accurate as conventional cephalometry in order to be taken as a standard of care in contemporary orthodontics. Objective of this study was to compare the accuracy of linear cephalometric measurements on scanned cephalograms with manual tracing as the gold standard. Cephalometric analysis of specified linear measurements was performed on cephalometric radiogra...
متن کاملAccuracy of Angular Cephalometric Measurements with Scanned Lateral Cephalograms
Digital Cephalometry is fast becoming the standard of care in contemporary orthodontic diagnosis. Before it can completely take over the traditional methods, it must be demonstrated that it is as accurate as conventional cephalometric radiography. This study was done to compare the accuracy of angular cephalometric measurements on scanned cephalograms with manual tracing as the gold standard. C...
متن کاملA comparison on dentofacial cephalometric measurements between two mouth breathing groups with anterior and posterior obstructions of nasal airway
A comparison on dentofacial cephalometric measurements between two mouth breathing groups with anterior and posterior obstructions of nasal airway zaeim* - Dr. M.R. Baghersad** Dr. M.H. Toodeh * - Assistant Professor of Oral Orthodontics Dept. - Faculty of Dentistry - Yazd University of Medical Sciences. ** - Dentist. Background and aim: The goal of this study was to compare dentofacial cep...
متن کاملComparison of cephalometric radiographs obtained from cone-beam computed tomography scans and conventional radiographs.
PURPOSE We evaluated whether measurements on conventional cephalometric radiographs are comparable to measurements on cone-beam computed tomography (CBCT)-constructed cephalometric radiographs taken from human skulls. MATERIALS AND METHODS The CBCT scans and conventional cephalometric radiographs were made using 40 dry skulls. With I-Cat Vision software (Imaging Sciences International, Inc, H...
متن کاملA comparison between 2D and 3D cephalometry on CBCT scans of human skulls.
The purpose of this study was to evaluate whether measurements on conventional cephalometric radiographs are comparable with 3D measurements on 3D models of human skulls, derived from cone beam CT (CBCT) data. A CBCT scan and a conventional cephalometric radiograph were made of 40 dry skulls. Standard cephalometric software was used to identify landmarks on both the 2D images and the 3D models....