Ektachem slides for direct potentiometric determination of sodium in plasma: effect of natremia, blood pH, and type of electrolyte reference fluid on concordance with flame photometry and other potentiometric methods.

نویسندگان

  • A Boeyckens
  • J Schots
  • H Vandenplas
  • F Senesael
  • W Goedhuys
  • F K Gorus
چکیده

With electrolyte reference fluid (ERF)00, results from Kodak Ektachem slides for the direct potentiometric assay of sodium in plasma were significantly correlated with results from flame photometry, but also appeared to be systematically higher, especially in hypernatremic patients. Indirect potentiometry with the Technicon RA-1000 yielded intermediate values. In 23 hypernatremic patients with greater than or equal to 6 mmol/L difference in sodium between Ektachem ERF00 and flame photometry, a clinical survey disclosed the frequent association of large between-method differences with renal failure, diabetes mellitus, and gastrointestinal disease. However, there was no correlation between differences in sodium on the one hand and anion gaps or (lipo)protein concentrations on the other, nor did in vitro addition studies implicate metabolites that often accumulate in the above-mentioned disorders. Unlike indirect methods, sodium measurements by direct potentiometry on Ektachem and Corning were influenced by in vitro changes of pH between 7.0 and 7.9. However, in a group of patients that included many acidotic individuals, between-method differences in sodium appeared not significantly correlated with in vivo blood pH. Use of the equitransferant ERF04 on Ektachem strongly diminishes the systematic differences with flame photometry, reduces the pH-dependency of the results to that of the direct Corning method, and brings the mean analytical recovery of sodium to below 95% (instead of 115% previously) without affecting the ability of Ektachem slides to avoid spuriously low results in the presence of increased (monoclonal) protein concentrations.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Direct potentiometric determination of potassium and sodium in blood, plasma, and serum.

A potentiometric analyzer, developed to directly measure potassium and sodium concentrations, was evaluated on aqueous solutions, whole blood, serum, and plasma. The analyzer consists of three electrodes-sodium, potassium, and reference-mounted in a fIowcell configuration, and a modified digital pH meter, which displays the ion concentrations directly. Volume of the cell is about 100 l. The ele...

متن کامل

Evaluation of a direct potentiometric method for sodium and potassium used in the Du Pont aca.

We evaluated an accessory that enables the Du Pont aca discrete analyzer to measure Na+ and K+ by direct potentiometry (aca/ISE). Na+ and K+ gave linear responses in both the blood and urine modes, with no carryover. No interfering species were identified in the blood mode. Intra-assay and interassay precision for Na+ and K+ were more than adequate and analytical recoveries comparable to those ...

متن کامل

Potentiometric analysis for sodium and potassium in biological fluids.

Results obtained with a potentiometric analyzer, NOVA 1, specific for sodium and potassium, were compared with those by flame photometry. Both instruments showed linearity within a physiological range of sodium and potassium concentrations and had similar precisions. Volume displacements from addition of albumin or Intralipid to aqueous samples yielded the predicted lower flame-photometric resu...

متن کامل

Sodium measurements in multiple myeloma: two techniques compared.

Sodium was determined by flame photometry and by direct potentiometry in 56 serum or plasma samples from 24 patients with multiple myeloma or macroglobulinemia. We observed differences between the two techniques as large as 17 mmol/L (12%). The flame-photometric values decreased relative to the direct-potentiometric values as protein increased or water content decreased. Moreover, the two sodiu...

متن کامل

Construction of S?-Selective Electrode and Thermodynamic Study of the Ternary Aqueous Mixed Electrolyte System (SrCl2, KG, H20) Using Potentiometric Method

In order to preparing strontium ion selective electrode 6-(4- nitropheny1)-2-pheny14, 4- dipropy1-3, 5-diaza-bicyclo [3, 1, 0] hex-2-ene (NPDBH) was used as an ionophore. This electrode responds to Sr (II)ion with a sensitivity of 28.2 ± 0.5 mV/decade over the range 1.0 x 10-6 to 1.0 Mat pH 3.0-10.0. Thelimit of detection was 2.4 x 10-7 M. The influences of membrane composition, the pH of the t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 38 1  شماره 

صفحات  -

تاریخ انتشار 1992