A monte carlo study of restricted diffusion: Implications for diffusion MRI of prostate cancer.

نویسندگان

  • Nima Gilani
  • Paul Malcolm
  • Glyn Johnson
چکیده

PURPOSE Diffusion MRI is used frequently to assess prostate cancer. The prostate consists of cellular tissue surrounding fluid filled ducts. Here, the diffusion properties of the ductal fluid alone were studied. Monte Carlo simulations were used to investigate ductal residence times to determine whether ducts can be regarded as forming a separate compartment and whether ductal radius could determine the Apparent Diffusion Coefficient (ADC) of the ductal fluid. METHODS Random walks were simulated in cavities. Average residence times were estimated for permeable cavities. Signal reductions resulting from application of a Stejskal-Tanner pulse sequence were calculated in impermeable cavities. Simulations were repeated for cavities of different radii and different diffusion times. RESULTS Residence times are at least comparable with diffusion times even in relatively high grade tumors. ADCs asymptotically approach theoretical limiting values. At large radii and short diffusion times, ADCs are similar to free diffusion. At small radii and long diffusion times, ADCs are reduced toward zero, and kurtosis approaches a value of -1.2. CONCLUSIONS Restricted diffusion in cavities of similar sizes to prostate ducts may reduce ductal ADCs. This may contribute to reductions in total ADC seen in prostate cancer. Magn Reson Med 77:1671-1677, 2017. © 2016 International Society for Magnetic Resonance in Medicine.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

بررسی ارزش Diffusion Weighted Imaging در تصاویر MRI برای تشخیص سرطان پروستات

Background: Prostate cancer is the third leading cause of death and is the most common cause of cancer in elderly men. Regarding to the low accuracy of screening methods such as prostate-specific antigen (PSA), Digital Rectal Examination (DRE) and trans rectal ultrasound (TRUS) in detection and localization of tumor, Magnetic Resonance Imaging (MRI) and Diffusion Weighted Imaging (DWI) attracte...

متن کامل

Signal Intensity of High B-value Diffusion-weighted Imaging for the Detection of Prostate Cancer

Background: Diffusion-weighted imaging (DWI) is a main component of multiparametric MRI for prostate cancer detection. Recently, high b value DWI has gained more attention because of its capability for tumor characterization. Objective: To assess based on histopathological findings of transrectal ultrasound (TRUS)-guided prostate biopsy as a reference, an...

متن کامل

Effect of Gold Nanoparticles on Prostate Dose Distribution under Ir-192 Internal and 18 MV External Radiotherapy Procedures Using Gel Dosimetry and Monte Carlo Method

Background: Gel polymers are considered as new dosimeters for determining radiotherapy dose distribution in three dimensions.Objective: The ability of a new formulation of MAGIC-f polymer gel was assessed by experimental measurement and Monte Carlo (MC) method for studying the effect of gold nanoparticles (GNPs) in prostate dose distributions under the internal Ir-192 and external 18MV radiothe...

متن کامل

Monte Carlo Simulation of Prostate Intensity Modulated Radiotherapy Using PRIMO Software: A Feasibility Study

Introduction: Nowadays Intensity Modulated Radiotherapy (IMRT) is a common method for treating prostate cancers. Must of the Monte Carlo software cannot simulate the IMRT procedures due to inability of these soft wares to simulate the multi leaf collimator (MLC) positions or movements. A new user-friendly software based on the PENELOPE Monte Carlo code named PRIMO was published...

متن کامل

A Monte Carlo study of the effects of cell membrane permeability on DWI-MRI contrast with oscillating diffusion gradients

Introduction: Recent interest in the use of oscillating diffusion gradients in diffusion-weighted magnetic resonance imaging (DWI-MRI) stems from simulated and experimental results indicating that, for given gradient performance parameters (max. amplitude, slew rate), an oscillating gradient spin echo (OGSE) sequence is capable of sampling shorter diffusion times than conventional pulsed gradie...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Magnetic resonance in medicine

دوره 77 4  شماره 

صفحات  -

تاریخ انتشار 2017