Pacemaker dependency after pacemaker implantation.
نویسندگان
چکیده
BACKGROUND Pacemaker dependency (PD) can be defined as the risk of serious injury or death from sudden pacemaker failure, an event more dangerous than progressive rate decrease. The aim of this study was to evaluate the incidence of PD during long-term follow-up after pacing system implantation. METHODS AND RESULTS The study included 3638 patients (mean age 65.3 +/- 10.2 years). Indications for pacing were sick sinus syndrome (SSS) in 1315 patients, atrioventricular block (AVB) in 1482, AVB and SSS in 478 and atrial fibrillation (AF) with bradycardia in 363 patients. The mean follow-up was 4.8 +/- 1.8 years. Pacemaker dependency was defined as the absence of an intrinsic rhythm of 30 beats/min during back-up pacing and after switching off the pacemaker. If any significant symptoms of bradycardia developed or if the underlying rhythm did not appear (asystole > 5 s) the pacing was restarted. Pacemaker dependency was observed in 76 (2.1%) of the 3638 patients . In this subgroup pacing indications were SSS in 8 (0.6%) of 1315 patients, AVB in 52 (3.5%) of 1482, SSS and AVB in 15 (3.1%) of 478 and AF with bradycardia in 1 (0.3%) of 363. Patients with AVB had a significantly higher incidence of PD than patients with SSS or AF (p < 0.001, p < 0.005, respectively). A total of 139 patients suffered from myocardial infarction and 106 patients had a temporary pacing prior to pacemaker implantation. The majority of these patients were pacemaker dependent (p < 0.001). CONCLUSIONS In our study PD occurred very rarely, being found in 2.1% of all patients. Patients with AVB have a significantly higher incidence of PD than patients with SSS or AF. Temporary pacing prior to pacemaker implantation and previous myocardial infarction indicate patients at risk of PD development. (Cardiol J 2007; 14: 83-86).
منابع مشابه
Erosive Pressure Dermatitis Associated with Cardiac Pacemaker
Erosive dermatitis is a skin reaction associated with implantable cardiac devices (ie, pacemakers and cardioverter defibrillators). We report a 65-year-old man with a history of several cerebrovascular attacks who developed an erythematous crusted erosive patch over the pacemaker site after implantation of two subsequent pacemakers. We suggest that physical irritation may be a trigger factor fo...
متن کاملPacemaker lead endocarditis with hiccups (Kalayci)
Background: Lead-related infections that might develop after pacemaker implantation associated with high mortality and morbidity rates are challenging to manage and pose high-cost. Patients with lead-related infections usually present with fever, chills and fatigue and the treatment can be challenging unless the implant system is extracted. Case presentation: A 66-year old male patient who und...
متن کاملComplete Congenital Heart Block in a Neonatal Lupus Erythematosus Associated with Pulmonary Involvement without Pacemaker Implantation: A Case Report
Background: Neonatal lupus erythematosus is an uncommon disease. Congenital complete heart block (CCHB) usually happens in neonates with maternal systemic lupus erythematosus. The most prevalent presentation of CCHBis bradycardiathatcanbediagnosed through an electrocardiogram. Case report: Here in, we present the case of a full-term male neonate with gestational age of 37 weeks and birth weigh...
متن کاملPacemaker Dependency after Cardiac Surgery: A Systematic Review of Current Evidence
BACKGROUND Severe postoperative conduction disturbances requiring permanent pacemaker implantation frequently occur following cardiac surgery. Little is known about the long-term pacing requirements and risk factors for pacemaker dependency in this population. METHODS We performed a systematic review of the literature addressing rates and predictors of pacemaker dependency in patients requiri...
متن کاملPacemaker Twiddler's Syndrome
A 76-yr-old man with unipolar ventricular pacemaker, previously implanted in the right ventricular apex, presented with syncopal attack and twitching of the right pectoralis muscle. He finally was diagnosed as having Twiddler's syndrome. The patient had a pulse rate of 36/min and cannon waves in the neck veins. Chest radiography showed a dislodged pacing lead completely wrapped around the pulse...
متن کاملPermanent pacemaker implantation after aortic valve replacement: Long-term dependency or rhythm recovery?
INTRODUCTION Conduction disturbances requiring permanent pacemaker (PM) implantation occur in 3-12% of patients after aortic valve replacement (AVR). Our aim was to assess long-term PM dependency and its predictors in these patients. METHODS We conducted a retrospective study of all consecutive patients undergoing permanent PM implantation after AVR between January 2004 and December 2010. Abs...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Cardiology journal
دوره 14 1 شماره
صفحات -
تاریخ انتشار 2007