Tolerability of Repeated Application of Transcranial Electrical Stimulation with Limited Outputs to Healthy Subjects.
نویسندگان
چکیده
BACKGROUND The safety and tolerability of limited output transcranial electrical stimulation (tES) in clinical populations support a non-significant risk designation. The tolerability of long-term use in a healthy population had remained untested. OBJECTIVE We tested the tolerability and compliance of two tES waveforms, transcranial direct current stimulation (tDCS) and modulated high frequency transcranial pulsed current stimulation (MHF-tPCS) compared to sham-tDCS, applied to healthy subjects for three to five days (17-20 minutes per day) per week for up to six weeks in a communal setting. MHF-tPCS consisted of asymmetric high-frequency pulses (7-11 kHz) having a peak amplitude of 10-20 mA peak, adjusted by subject, resulting in an average current of 5-7 mA. METHOD A total of 100 treatment blind healthy subjects were randomly assigned to one of three treatment groups: tDCS (n = 33), MHF-tPCS (n = 30), or sham-tDCS (n = 37). In order to test the role of waveform, electrode type and montage were fixed across tES and sham-tDCS arms: high-capacity self-adhering electrodes on the right lateral forehead and back of the neck. We conducted 1905 sessions (636 sham-tDCS, 623 tDCS, and 646 MHF-tPCS sessions) on study volunteers over a period of six weeks. RESULTS Common adverse events were primarily restricted to influences upon the skin and included skin tingling, itching, and mild burning sensations. The incidence of these events in the active tES treatment arms (MHF-tPCS, tDCS) was equivalent or significantly lower than their incidence in the sham-tDCS treatment arm. Other adverse events had a rarity (<5% incidence) that could not be significantly distinguished across the treatment groups. Some subjects were withdrawn from the study due to atypical headache (sham-tDCS n = 2, tDCS n = 2, and MHF-tPCS n = 3), atypical discomfort (sham-tDCS n = 0, tDCS n = 1, and MHF-tPCS n = 1), or atypical skin irritation (sham-tDCS n = 2, tDCS n = 8, and MHF-tPCS n = 1). The rate of compliance, elected sessions completed, for the MHF-tPCS group was significantly greater than the sham-tDCS group's compliance (p = 0.007). There were no serious adverse events in any treatment condition. CONCLUSION We conclude that repeated application of limited output tES across extended periods, limited to the hardware, electrodes, and protocols tested here, is well tolerated in healthy subjects, as previously observed in clinical populations.
منابع مشابه
Effect of Transcranial Direct Current Stimulation on Auditory-Verbal Memory in Healthy Elderly
Background and purpose: Auditory-verbal memory decreases with age. One method to compensate this weakness is transcranial direct current stimulation. The current study investigated the effect of Anodal Transcranial Direct Current Stimulation on auditory-verbal memory performance of healthy elderly people. Materials and methods: In a randomized clinical trial, 42 healthy subjects with no histor...
متن کاملThe tolerability of transcranial electrical stimulation used across extended periods in a naturalistic context by healthy individuals
Transcranial electrical stimulation (tES) is one of the most widely implemented forms of non-invasive neuromodulation in basic and clinical neuroscience. Further, the use of tES by healthy populations for various purposes is growing widespread daily. The effects of tES protocols on the skin and other tissues has remained uncharacterized when used across extended periods of time by healthy indiv...
متن کاملMethodological Dimensions of Transcranial Brain Stimulation with the Electrical Current in Human
Transcranial current stimulation (TCS) is a neuromodulation method in which the patient is exposed to a mild electric current (direct or alternating) at 1-2 mA, resulting in an increase or a decrease in the brain excitability. This modi.cation in neural activities can be used as a method for functional human brain mapping with causal inferences. This method might also facilitate the treatments ...
متن کاملEffectiveness of direct electrical stimulation from the skull on depression symptoms in male patients with post-traumatic stress disorder due to war
The purpose of this study was to determine the effectiveness of direct electrical stimulation from the skull on depression symptoms in men suffering from post-traumatic stress disorder in war. The research design was a semi-experimental design with repeated tests. The sample included 15 patients with post-traumatic stress disorder men who were admitted to the Delaram Psychiatric Hospital and we...
متن کاملComparison of the effect of Transcranial Direct Current Stimulation (tDCS (and Transcranial Random Noise Stimulation (tRNS (combined with cognitive training on working memory performance of people with attention deficit/hyperactivity disorder
This study aimed to comparison of the effect of Transcranial Direct Current Stimulation (tDCS) and Transcranial Random Noise Stimulation (tRNS) combined with cognitive training on working memory performance of people with attention deficit/hyperactivity disorder. For this purpose, 45 children with attention deficit hyperactivity disorder in zahedan city were purposefully selected as the researc...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Brain stimulation
دوره 9 5 شماره
صفحات -