Standardization of serum creatinine and estimated GFR in the Kidney Early Evaluation Program (KEEP).

نویسندگان

  • Lesley A Stevens
  • Nicholas Stoycheff
چکیده

BACKGROUND Creatinine calibration by clinical laboratories is important because variability among assays adversely affects the accuracy of glomerular filtration rate (GFR) estimation. We describe the calibration of creatinine assays used in the National Kidney Foundation Kidney Early Evaluation Program (KEEP). METHODS Creatinine values were requested for 200 samples at each of the 2 KEEP laboratories, Satellite Laboratory Services, LLC (2000 to 2005) and Clinical Laboratory Services (CLS; 2005 to present), for comparison with samples at the Cleveland Clinic Research Laboratory (CCRL). Linear regression and Deming regression were used to obtain slopes adjusted for measurement error and regression to the mean. RESULTS After exclusion of outliers, mean creatinine level in 184 samples was 0.94 mg/dL at Satellite compared with 0.89 mg/dL at CCRL. Deming regression showed a slope of 1.003 (95% confidence interval (CI), 0.99 to 1.02; P < 0.001) and intercept of -0.04 (95% CI, -0.59 to -0.02; P = 0.003) with R(2) = 0.9853. Final calibration consists of intercept alone because of a small slope. After exclusion of outliers, mean creatinine level in 199 samples was 1.06 mg/dL at CLS compared with 0.96 mg/dL at CCRL. Deming regression showed a slope of 1.08 (95% CI, 1.07 to 1.09; P < 0.001) and intercept of -0.18 (95% CI, -0.19 to -0.17; P < 0.001) with R(2) = 0.9939. GFR estimates were minimally affected by the Satellite calibration. At a serum creatinine value of 1 mg/dL, the change in estimated GFR was 1 mL/min/1.73 m(2) after calibration. Conversely, higher range GFR estimates were affected by calibration of the CLS creatinine assay. At a serum creatinine value of 1 mg/dL, the GFR estimate was 6 mL/min/1.73 m(2) higher after calibration. CONCLUSION Calibration of KEEP creatinine measurements had a greater impact on the current laboratory than on the laboratory previously used. The calibration process has worked to decrease overestimation of eGFR at the high range and decrease misclassification bias.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Early Acute Kidney Injury based on Serum Creatinine or Cystatin C in Intensive Care Unit after Major Trauma

Background: Acute kidney injury (AKI) is a common problem in critically ill patients and is independently associated with increased morbidity and mortality. Recently, serum cystatin C has been shown to be superior to creatinine in early detection of renal function impairment. We compared estimated GFR based on serum cystatin C with estimated GFR based on serum creatinine for early detection of ...

متن کامل

مقایسه سطح سرمی بیومارکر NGAL قبل و بعد پیوند با شاخص‌های عملکرد گرافت

Background & Aims: Diagnosis of poor graft function by modern biomarkers is a step to early detection of injuries to the kidneys. Therefore, in this study, serum NGAL was evaluated in renal transplant recipients and compared with creatinine and glomerular filtration rate (GFR) using CKD-Epi equation. Materials & Methods: This case-control study was performed at Imam Khomeini Teaching Hospital,...

متن کامل

Effects of Linear and Nonlinear Periodized Resistance Training on some of Kidney Functional Parameters in Women with Abdominal Obesity

Introduction: The aim of this study was to determine the effects of linear and nonlinear periodized resistance training on serum levels of creatinine, glomerular filtration rate (GFR), and creatinine clearance in women with abdominal obesity.    Materials & Methods: This study was conducted on 42 women who were randomly assigned into linear periodized (LP) resistance training (N=15, age: 40.4...

متن کامل

Determining an accurate method to estimate GFR in renal transplant recipients with stable serum creatinine levels

Introduction:Detecting renal allograft dysfunction early will allow timely diagnosis and treatment. There is no objective recommendation by national kidney societies for glomerular filtration rate (eGFR) estimation in post-transplant setting. 99mTc-DTPA Technetium-99m Diethylene triamine penta acetic acid) renogram can identify early renal dysfunction much before ser...

متن کامل

KEEP 2012 The Synergistic Relationship Between Estimated GFR and Microalbuminuria in Predicting Long-term Progression to ESRD or Death in Patients With Diabetes: Results From the Kidney Early Evaluation Program (KEEP)

Introduction: Chronic kidney disease may complicate diabetes, often manifesting with reduced glomerular filtration rate (GFR), albuminuria, or both. Although greater albuminuria and lower estimated GFR both predict adverse prognosis, whether a synergistic prognostic interaction occurs in patients with diabetes has not been defined in a large national cohort study. Methods: We used 2000-2011 dat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • American journal of kidney diseases : the official journal of the National Kidney Foundation

دوره 51 4 Suppl 2  شماره 

صفحات  -

تاریخ انتشار 2008