The reliability of the Frankfort Horizontal in roentgenographic cephalometry.

نویسندگان

  • H Pancherz
  • K Gökbuget
چکیده

This longitudinal investigation was undertaken to assess the reliability of the Frankfort Horizontal line (FH) when using either anatomical Porion (Po-a) or machine Porion (Po-m) as reference landmarks. Lateral head films (22 pairs) from subjects at the ages of 11 and 14 years were analysed twice. The results revealed that: (i) the registration error of Po-a was larger than of Po-m; (ii) for Po-a the registration error from the 11 year head films was approximately twice as large as from the 14 year head films; (iii) Po-m was, on average, located approximately 9 mm below and 2 mm anterior to Po-a; (iv) during the 3 years of observation, Po-m changed its position downward markedly more than Po-a; (v) due to the diverging location of machine Porion (Po-m) in relation to true Porion (Po-a) and the large change of Po-m with time, the FH was affected considerably. It was concluded that machine Porion was unsuitable for the construction of the FH. A misjudgement of the reference line may result in diagnostic misinterpretations and lead to false conclusions in longitudinal studies, e.g. when the outcome of a particular treatment procedure is evaluated.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of accuracy of transfer of the maxillary occlusal cant of two articulators using two facebow/semi-adjustable articulator systems: An in vivo study

AIM The aim of this study was to compare the accuracy of the angle made by Frankfort horizontal plane-occlusal plane on maxillary casts, mounted using the respective facebows on Artex Amann Girrbach and Hanau Wide-vue semi-adjustable articulators with cephalometrically derived Frankfort horizontal plane-occlusal plane angle as a control. SUBJECTS AND METHODS Maxillary casts of 30 subjects wer...

متن کامل

A Comparison of Two Methods to Articulate a Maxillary Cast with Lateral Cephalometry

A COMPARISON OF TWO METHODS TO ARTICULATE A MAXILLARY CAST WITH LATERAL CEPHALOMETRY Laura H. Lux D.D.S Marquette University, 2014 The Kois Dento-Facial Analyzer, an arbitrary articulation system, is used by clinicians to articulate and evaluate clinical cases. There is, however, limited information for understanding how the Kois Dento-Facial Analyzer should be utilized. Dr. Kois and Dr. Lee or...

متن کامل

Validity & reliability of cephalometric measurements in traditional versus digitized cephalometry

Aim: Film digitization is generally used to prevent potential damage or loss of original films. The method of film processing has been changing from wet to dry processing due to recent trends toward digitization of medical imaging. Materials & Methods: 50 Lateral cephalometric radiograms were used in this study. All radiographs were viewed under standardized conditions& traced. Eleven landmarks...

متن کامل

Reproducibility of Frankfort Horizontal Plane on 3D Multi-Planar Reconstructed MR Images

OBJECTIVE The purpose of this study was to determine the accuracy and reliability of Frankfort horizontal plane identification using displays of multi-planar reconstructed MRI images, and propose it as a sufficiently stable and standardized reference plane for craniofacial structures. MATERIALS AND METHODS MRI images of 43 subjects were obtained from the longitudinal population based cohort s...

متن کامل

A comparative study between data obtained from conventional lateral cephalometry and reconstructed three-dimensional computed tomography images

OBJECTIVES The aim of this study was to verify the concordance of the measurement values when the same cephalometric analysis method was used for two-dimensional (2D) cephalometric radiography and three-dimensional computed tomography (3D CT), and to identify which 3D Frankfort horizontal (FH) plane was the most concordant with FH plane used for cephalometric radiography. MATERIALS AND METHOD...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European journal of orthodontics

دوره 18 4  شماره 

صفحات  -

تاریخ انتشار 1996