An evaluation of the Kodak glucose/ BUN analyser including experience with proposed testing protocols
نویسندگان
چکیده
منابع مشابه
Abstracts/Sommaires/Zusammenfassungen
An evaluation of the Kodak glucose/BUN analyzer including experience with proposed testing protocols An evaluation of the analysis of serum urea and plasma_glucose on the Kodak Ektachem GLU/BUN()analyzer is described. It incorporates the experimental design and statistical methods outlined in the Proposed Standard for Establishing Performance Claims (PSEP) (1) for clinical chemical methods PSEP...
متن کاملEvaluation of the Kodak Ektachem DT60 analyser for sodium, potassium, glucose and urea
The Kodak Ektachem DT60/E analyser is a desk-top analyser which uses thin-film ’dry’ chemistry technology to perform colorimetric and potentiometric analyses. The analyser is simple to operate and the slides are claimed to be stablefor up to oneyear if stored at 4 C. Calibration is said to be required only once every three months. Results presented in this paper substantiate these claims and sh...
متن کاملExtended clinical trial and evaluation of glucose determination with the Eastman Kodak Ektachem GLU/BUN Analyzer.
We followed the "abbreviated precision protocol" of the National Committee for Clinical Laboratory Standards for the evaluation of precision, accuracy, and carryover in analyses for glucose with the "Ektachem." We analyzed 760 clinical samples by this technique, by the FDA Proposed Class Standard glucose reference method, and with the Beckman System I GLU/BUN Analyzer. Precision and accuracy we...
متن کاملExcessive testing in emergent evaluation of children with first unprovoked seizure
Abstract Backround: The first episode of an afebrile seizure is a common cause of admission of children to emergency departments. Alot of tests are routinely performed for these patients. The cost of such an evaluation is high and benefits are doubtful. We conducted this study in order to evaluate the results of the tests and find out what tests are necessary for children with first unp...
متن کاملEvaluation of an engineering model of the "EKTACHEM" analyzer for glucose and urea assay.
We report results of a 21-week evaluation of an engineering model of the Kodak “EKTACHEM Glu/BUN Analyzer.” This novel clinical instrument measures glucose and “urea nitrogen” (actually, urea) in a minimum of 30 j.tL of body fluids by use of the principles of thin, multilayer film analysis and reflectance spectrophotometry. We compared the performance of the instrument to that of the Dupont aca...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of Automatic Chemistry
دوره 3 شماره
صفحات -
تاریخ انتشار 1981