The effects of target motion in kV-CBCT imaging
نویسندگان
چکیده
BACKGROUND To study the impact of target motion in kV-CBCT imaging. MATERIAL/METHODS To simulate the respiratory movement, dynamic phantom was programmed to move in three-dimension with a period of four seconds and of two different amplitudes (PA1 and PA2). The targets of well defined geometries (cylinder, sphere, solid triangle, U-shaped and dumbbell) were made using wax. The static targets were CT imaged (reference image). Using CBCT, the targets in static and dynamic modes were imaged under full-fan beam. The line profiles along cranio-caudal direction, influence of target's initial moving phase and volume estimation using auto-contouring tool were used to analyze the effects of target motion on CBCT imaging. RESULTS Comparing the line profiles of targets in CBCT with CT, the length of average HU spread was reduced by 42.54±1.85%, except the cylindrical target which is by 19.35% for PA1. The percentage difference in reconstructed volume of static targets imaged using CBCT and CT (HU WW -500 to 0) ranges from -1.32% to -5.94%. The volume losses for targets imaged in dynamic mode PA1 ranges from 14.35% to 30.95% and for PA2 it was 21.29% to 43.80%. The solid triangle and cylindrical targets suffered the maximum and minimum volume losses respectively. CONCLUSIONS Non-gated CBCT imaging of the moving targets encounters significant loss of volumetric information, due to scatter artifacts. These may result in a systematic error in re-contouring when CBCT images are used for the re-planning work.
منابع مشابه
Comparative Study between Electronic Portal Imaging Device (EPID) and Cone Beam Computed Tomography (CBCT) for Radiation Treatment Verifications
Introduction: Electronic Portal Imaging Device (EPID) and Cone Beam Computed Tomography (CBCT) are the preferred tools of Image Guided Radiotherapy (IGRT) and Dose Guided Radiotherapy (DGRT) which have been used for Radiotherapy treatment verifications. As a result, the number of publications dealing with these two tools for radiation treatment verification has increased consi...
متن کاملProstate Intrafraction Motion Assessed by Simultaneous Kv
PROSTATE INTRAFRACTION MOTION ASSESSED BY SIMULTANEOUS KV FLUOROSCOPY AT MV DELIVERY by JUSTUS D. ADAMSON August 2009 Co-Advisor: Dr. Qiuwen Wu Co-Advisor: Dr. Jay Burmeister Major: Medical Physics Degree: Doctor of Philosophy Purpose: To investigate the use of a gantry mounted kV imager for prostate intrafraction motion measurement during simultaneous dose delivery. Materials & Methods: We dev...
متن کاملPhantom-based evaluation of dose exposure of ultrafast combined kV-MV-CBCT towards clinical implementation for IGRT of lung cancer
PURPOSE Combined ultrafast 90°+90° kV-MV-CBCT within single breath-hold of 15s has high clinical potential for accelerating imaging for lung cancer patients treated with deep inspiration breath-hold (DIBH). For clinical feasibility of kV-MV-CBCT, dose exposure has to be small compared to prescribed dose. In this study, kV-MV dose output is evaluated and compared to clinically-established kV-CBC...
متن کاملPTV margin definition in hypofractionated IGRT of localized prostate cancer using cone beam CT and orthogonal image pairs with fiducial markers
PURPOSE To evaluate PTV margins for hypofractionated IGRT of prostate comparing kV/kV imaging or CBCT. PATIENTS AND METHODS Between 2009 and 2012, 20 patients with low- (LR), intermediate- (IR) and high-risk (HR) prostate cancer were treated with VMAT in supine position with fiducial markers (FM), endorectal balloon (ERB) and full bladder. CBCT's and kV/kV imaging were performed before and ad...
متن کاملFeasibility study on effect and stability of adaptive radiotherapy on kilovoltage cone beam CT
BACKGROUND We have analyzed the stability of CT to density curve of kilovoltage cone-beam computerized tomography (kV CBCT) imaging modality over the period of six months. We also, investigated the viability of using image value to density table (IVDT) generated at different time, for adaptive radiotherapy treatment planning. The consequences of target volume change and the efficacy of kV CBCT ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 75 شماره
صفحات -
تاریخ انتشار 2010