Automatic and visual reproducibility of perfusion and function measures for myocardial perfusion SPECT

نویسندگان

  • Yuan Xu
  • Sean Hayes
  • Iftikhar Ali
  • Terrence D. Ruddy
  • R. Glenn Wells
  • Daniel S. Berman
  • Guido Germano
  • Piotr J. Slomka
چکیده

BACKGROUND We define the repeatability coefficients (RC) of key quantitative and visual perfusion and function parameters that can be derived by the QGS/QPS automated software and by expert visual observer from gated myocardial perfusion SPECT (MPS) scans. METHODS Standard QGS/QPS algorithms have been applied to derive quantitative perfusion and function parameters in 200 99mTc-tetrofosmin rest/stress MPS scans, obtained in 100 consecutive patients who underwent 2 separate gated rest/stress scans on the same camera. Variables included stress, rest, and ischemic total perfusion deficit (TPD), ejection fraction, motion, and thickening. Visual perfusion/motion scores were derived by an expert reader using randomized scan order and normalized to % myocardium. RESULTS Quantitative and visual parameters were highly reproducible with smaller RC for some quantitative measures as compared to visual measures (P < .0001). RC for quantitative measures were 3.3% for stress TPD, 1.8% for rest TPD, and 3.2% for ischemic TPD and for visual scoring 4.8% for stress, 3.8% for rest, and 4.3% for ischemic (P ≤ .002). The results in each vessel territory showed that in the right coronary artery (RCA) territory the quantitative approach had improved reproducibility as compared to visual reading. Visual thickening scoring was more reproducible than motion scoring (P < .0001). CONCLUSIONS This study demonstrates that standard perfusion and function parameters derived from MPS by visual or quantitative analysis are highly reproducible with some advantages to the quantitative approach.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Myocardial perfusion SPECT: Perfusion quantification

Different software tools for quantification of myocardial perfusion SPECT (MPS) studies are routinely used. Several perfusion parameters can be computed automatically.  Interpretation of the MPS should start with visual inspection of the rotating planar images, visual analysis of reconstructed SPECT slices and then quantitative analysis to confirm the visual impression. Quantification should be...

متن کامل

Semi-quantitative segmental perfusion scoring in myocardial perfusion SPECT: visual vs. automated analysis

Introduction: It is recommended that the physician apply at least a semi-quantitative segmental scoring system in myocardial perfusion SPECT.  We aimed to assess the agreement between automated semi-quantitative analysis using QPS (quantitative Perfusion SPECT) software and visual approach for calculation of summed stress  score (SSS), summed rest score (SRS) and summed difference score (SDS). ...

متن کامل

Evaluation of myocardial perfusion and function after kidney transplantation by Gated SPECT myocardial perfusion scintigraphy

Introduction: The aim of this study was to evaluate the effect of successful kidney transplantation (KT) on myocardial perfusion and left ventricular function by both qualitative (visual) interpretation and semiquantitative parameters, using myocardial perfusion scintigraphy with gated-single photon emission computed tomography (gated-SPECT) in patients suffering from end-stage renal disease. ...

متن کامل

Dipyridamole stress and rest gated 99mTc-sestamibi myocardial perfusion SPECT: left ventricular function indices and myocardial perfusion findings

  Introduction: We investigated the difference in left ventricular ejection fraction (LVEF) and end-systolic volume(ESV) measured by gated myocardial perfusion SPECT (GSPECT) in the post-dipyridamole stress and rest periods, and compared the results with the perfusion patterns found in the conventional non-gated tomograms. Methods: 297 consecutive patients were studie...

متن کامل

The role of oral dipyridamole stress gated SPECT in assessing the response of the left ventricle to stress: Re-evaluation of an old method

Introduction: We aimed to assess whether the vasodilator effect of oral dipyridamole on the left ventricular systolic function in patients with suspected CAD is different from that of intravenous (IV) dipyridamole using Tc-99m MIBI myocardial perfusion gated SPECT. Methods: Eighty-nine patients (17 M / 72 W; 61 ± 10 years) were enrolled in this study. The patients underwent a dipyridamole stre...

متن کامل

Comparison of transient ischemic dilation ratios in SPECT and SPECT-CT myocardial perfusion imaging in the low pre-test probability group

Introduction: The main purpose of this study was to compare transient ischemic dilation (TID) ratios in SPECT-low dose CT and SPECT Myocardial Perfusion Imaging (MPI) by application of different quantitative programs and quantify the possible shift in the upper normal limits of TID ratio in the SPECT-CT MPI. Methods: 149 Patients with low pre-test probability for coronary artery disease (CAD),...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 17  شماره 

صفحات  -

تاریخ انتشار 2010