Spectroscopic diagnostics of the plasma in the cathode region of a nitrogen glow discharge

نویسندگان

  • A. Margulis
  • J. Jolly
چکیده

2014 Spatially resolved spectroscopic diagnostics such as plasma-induced emission, laser-induced fluorescence and laser optogalvanic spectroscopy are used to characterize the cathode sheath and the negative glow of an abnormal glow dc discharge in nitrogen. These diagnostics provide local information on the excitation and ionization functions, on the concentrations of ions and on the rotational temperature of the various species in the plasma of the cathode region. Revue Phys. Appl. 24 (1989) 323-329 MARS 1989, Classification Physics Abstracts 52.80 52.70

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Influence of the interelectrode distance on the production of nanoparticles by means of atmospheric pressure inert gas DC glow discharge

This work is aimed at investigating the influence of the inter-electrode spacing on the production rate and size of nanoparticles generated by evaporating a cathode on an atmospheric pressure dc glow discharge. Experiments are conducted in the configuration of two vertically aligned cylindrical electrodes in upward coaxial flow with copper as a consumable cathode and nitrogen as a carrier gas. ...

متن کامل

Double Langmuir probe measurement of plasma parameters in a dc glow discharge

In this paper, plasma main characteristics such as electron mean temperature, electron number density, and oscillation frequency have been measured experimentally using the double Langmuir probe diagnostic system. In our experiment, the plasma was generated by applying the low pressure dc glow discharge in several common gases. The experimental results indicated the highest plasma density and o...

متن کامل

Chemistry in glow discharges of H2 / N2 mixtures. Diagnostics and modelling

A combined diagnostics and modelling of low pressure H2 /(10%)N2 plasmas generated in a hollow cathode (DC) reactor is present. Neutral and ion distributions are measured by mass spectrometry in the pressure range 0.8 − 8 Pa. Apart from N2 and H2, NH3 is observed in appreciable concentrations among the neutrals. Concerning the charged species, pure hydrogen and nitrogen ions are detected togeth...

متن کامل

Generation of Plasma Induced Flow Actuation by DC Glow-like Discharge in a Supersonic Flow

Plasma induced flow field modification is studied experimentally using non-equilibrium DC surface discharge in a Mach 3 supersonic flow. An array of small pin electrodes (φ = 3/32”) is used in streamwise plasma discharge configuration. The schlieren imaging shows that an oblique shock can be obtained with a volumetric glow discharge on the cathode with a relatively low current (as low as 50 mA)...

متن کامل

Evaluation of Nitrogen Diffusion in Plasma Nitrided Iron by Various

   Diffusion of nitrogen in plasma nitrided iron and structural evolution during the nitriding process were evaluated by several characterization techniques including optical microscopy (OM), microhardness depth profiling (HDP), scanning electron microscopy (SEM), x-ray diffraction (XRD), glow discharge optical emission spectroscopy (GDOES), and secondary ion mass spectroscopy (SIMS). Plasma ni...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016