Acute and critically ill peripartum cardiomyopathy and 'bridge to' therapeutic options: a single center experience with intra-aortic balloon pump, extra corporeal membrane oxygenation and continuous-flow left ventricular assist devices

نویسندگان

  • Sofie Gevaert
  • Yves Van Belleghem
  • Stefaan Bouchez
  • Ingrid Herck
  • Filip De Somer
  • Yasmina De Block
  • Fiona Tromp
  • Els Vandecasteele
  • Floor Martens
  • Michel De Pauw
چکیده

INTRODUCTION Peripartum cardiomyopathy (PPCM) patients refractory to medical therapy and intra-aortic balloon pump (IABP) counterpulsation or in whom weaning from these therapies is impossible, are candidates for a left ventricular assist device (LVAD) as a bridge to recovery or transplant. Continuous-flow LVADs are smaller, have a better long-term durability and are associated with better outcomes. Extra corporeal membrane oxygenation (ECMO) can be used as a temporary support in patients with refractory cardiogenic shock. The aim of this study was to evaluate the efficacy and safety of mechanical support in acute and critically ill PPCM patients. METHODS This was a retrospective search of the patient database of the Ghent University hospital (2000 to 2010). RESULTS Six PPCM-patients were treated with mechanical support. Three patients presented in the postpartum period and three patients at the end of pregnancy. All were treated with IABP, the duration of IABP support ranged from 1 to 13 days. An ECMO was inserted in one patient who presented with cardiogenic shock, multiple organ dysfunction syndrome and a stillborn baby. Two patients showed partial recovery and could be weaned off the IABP. Four patients were implanted with a continuous-flow LVAD (HeartMate II, Thoratec Inc.), including the ECMO-patient. Three LVAD patients were successfully transplanted 78, 126 and 360 days after LVAD implant; one patient is still on the transplant waiting list. We observed one peripheral thrombotic complication due to IABP and five early bleeding complications in three LVAD patients. One patient died suddenly two years after transplantation. CONCLUSIONS In PPCM with refractory heart failure IABP was safe and efficient as a bridge to recovery or as a bridge to LVAD. ECMO provided temporary support as a bridge to LVAD, while the newer continuous-flow LVADs offered a safe bridge to transplant.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Temporary Mechanical Circulatory Support: A Review of the Options, Indications, and Outcomes

Cardiogenic shock remains a challenging disease entity and is associated with significant morbidity and mortality. Temporary mechanical circulatory support (MCS) can be implemented in an acute setting to stabilize acutely ill patients with cardiomyopathy in a variety of clinical situations. Currently, several options exist for temporary MCS. We review the indications, contraindications, clinica...

متن کامل

Peripartum cardiomyopathy: review and practice guidelines.

Peripartum cardiomyopathy, a type of dilated cardiomyopathy of unknown origin, occurs in previously healthy women in the final month of pregnancy and up to 5 months after delivery. Although the incidence is low-less than 0.1% of pregnancies -morbidity and mortality rates are high at 5% to 32%. The outcome of peripartum cardiomyopathy is also highly variable. For some women, the clinical and ech...

متن کامل

The spectrum of haemodynamic support in cardiogenic shock: how to choose and use.

Copyright © Polskie Towarzystwo Kardiologiczne INTRODUCTION Cardiogenic shock is still the most important prognostic factor for short-term mortality in acute coronary syndromes, with mortality rates approaching 50% at 30 days [1, 2]. Haemodynamic support can be achieved by inotropics and/or vasopressors as well as mechanical means such as intra-aortic balloon pumping (IABP) or percutaneous impl...

متن کامل

Mechanical Circulatory Support of the Critically Ill Child Awaiting Heart Transplantation

The majority of children awaiting heart transplantation require inotropic support, mechanical ventilation, and/or extracorporeal membrane oxygenation (ECMO) support. Unfortunately, due to the limited pool of organs, many of these children do not survive to transplant. Mechanical circulatory support of the failing heart in pediatrics is a new and rapidly developing field world-wide. It is utiliz...

متن کامل

Percutaneous Ventricular Assist Devices and ECMO in the Management of Acute Decompensated Heart Failure

The successful treatment of acute decompensated heart failure continues to evolve with an increasing utilization of nondurable mechanical support devices. Indications for acute support have broadened to include their use as a bridge to recovery or decision (for durable ventricular assist devices [VADs] or heart transplant). Available devices have improved in terms of effectiveness, ease of inse...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 15  شماره 

صفحات  -

تاریخ انتشار 2011