[Vascular prosthesis infection in thoracic aorta surgery: review of the experience and a case report illustrating treatment with an unconventional technique].

نویسندگان

  • Ronaldo Ducceschi Fontes
  • Noedir Antônio Groppo Stolf
  • Júlio Cesar Marino
  • David Pamplona
  • Luis Francisco Avila
  • Sérgio Almeida Oliveira
چکیده

We report the case of a 37-year-old-female patient who had undergone a Bentall procedure at our service and returned with intense chest pain and acute aortic dissection type III, which was diagnosed and clinically treated. One year after this episode, this dissection expanded, and the patient underwent surgery with interposition of a Dacron graft in the descending aorta. In the immediate postoperative period, the patient experienced left bronchopneumonia and was discharged afebrile and in good condition. One month after discharge, she returned with fever and toxemia. Pleural empyema was diagnosed, and she underwent an exploratory thoracotomy that did not confirm this diagnosis, but revealed intense effusion thickening. Four months after the exploratory thoracotomy, Klebsiella pneumoniae and Enterobacter sp were isolated in a blood culture. Magnetic resonance imaging revealed shapes compatible with perigraft infection. With this clinical and laboratory picture, graft removal was indicated as was axillo-bifemoral grafting. Surgery was successfully performed, the patient was discharged in good condition, and remains well after a 57-month follow-up without complications. The methods used for diagnosis and treatment of prosthesis infection in thoracic aorta surgery are discussed.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Mycotic aortic aneurysm as a postsurgical complication: report of a case and review of the literature

Mycotic aneurysms are localized and irreversible dilatations of the arteries caused by weakening and damaging the arterial wall by an invasive organism establishing infective arteritis. Mycotic aneurysm of the thoracic aorta is a rare event; however, it can be fatal if not diagnosed early or not treated appropriately. Clinical findings are usually nonspecific; however, c...

متن کامل

BULL ET-INDUCED FALSE ANEURYSM OF THORACIC AORTA WITH A TEN YEAR LATENCY PERIOD IN A VICTIM OF THE IRAN-IRAQ WAR: REPORT OF A CASE

Traumatic false aneurysm of the thoracic aorta is not uncommon. But accordingly this case is unusual in its ten year delay between injury and presentation and treatment. A victim of the Iran-Iraq war is presented with a false aneurysm of the thoracic aorta ten years after a bullet injury to the chest and thoracic spine. Penetrating chest wounds, mechanisms of injury and diagnosis are also ...

متن کامل

Endovascular repair of traumatic pseudoaneurysm of the descending thoracic aorta: report of three cases and review of

 Abstract Traumatic descending thoracic aorta pseudo aneurysms have been treated traditionally with open surgery in the past, which have had noticeable rates of mortality and morbidity. A safer method of treatment for this disease is made possible with recent progress in endovascular treatment techniques. In this article, we present three cases of Traumatic descending thoracic aorta pseudo aneu...

متن کامل

First Iranian Experience of the Minimally Invasive Nuss Procedure for Pectus Excavatum Repair: A Case Series and Literature Review

Pectus excavatum is the most common congenital deformity of the chest wall. The most frequently used techniques include Ravitch (costochondral resection) and Nuss (minimally invasive pectus repair of pectus excavatum [MIRPE]). The Nuss technique includes using temporary metallic bars without costochondral resection to correct the chest wall deformity. Modified MIRPE can be learned easily and pe...

متن کامل

Conservative management of superior vena cava injury due to hemodialysis catheter placement: A case report and literature review

We reported the case of a 78-year old woman with the inadvertent superior vena cava injury resulting from hemodialysis catheter placement. The catheter was placed through the left internal jugular vein. Hemodynamics were stable. The initial chest film illustrated an extraluminal catheter and mediastinal widening. The patient did not have hemothorax. Computed tomography venography also confirmed...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Arquivos brasileiros de cardiologia

دوره 82 3  شماره 

صفحات  -

تاریخ انتشار 2004