Evaluation of the Antibiotic Removal Device.
نویسندگان
چکیده
A new system called an Antibiotic Removal Device (ARD), used for the removal of residual antibiotics in blood specimens, was studied in 300 patients diagnosed as clinically septic despite antimicrobial therapy. Blood specimens from these patients were processed with and without the ARD into aerobic and anaerobic media. There were 53 patients who had one or more positive blood culture bottles, for a total of 109 positive blood culture bottles. Of these 109 bottles, 33.9% were positive with ARD-processed blood in aerobic media, 24.8% with ARD-processed blood in anaerobic media, 22.9% with conventionally processed blood in aerobic media, and 18.3% with conventionally processed specimens in anaerobic media. After 6 h of incubation, 14 bottles with blood processed by the ARD and 9 bottles processed conventionally were positive; after 24 h, 48 bottles with blood processed by the ARD and 31 bottles processed conventionally were positive. The same organisms were isolated from both ARD- and conventionally processed blood, with four exceptions. The ARD system, when compared with a conventional system of blood specimen processing, significantly increased the detection of bacteremia and decreased the time required for its detection in patients clinically septic despite ongoing antimicrobial therapy.
منابع مشابه
Evaluation the efficiency of magnetic-metallic chitosan nanocomposite adsorbent in the removal of tetracycline antibiotic from aqueous solutions
Background and Objective: Antibiotics are considered due to health and environmental problems and therefore they counted as a major threat to human health. The aim of this study was to determine the absorption efficiency of magnetic-chitosan nanocomposite in the removal of antibiotic tetracycline from aqueous solutions. Materials and Method: In this study, the experiments were performed by spec...
متن کاملEvaluation of the Efficiency of photocatalytic UV/ peroxymonosulfate process in the removal of cefexime antibiotic from aqueous solutions
Background and Aim: Pharmaceuticals, especially antibiotics, are new contaminants that because of their cumulative nature, adverse effects and drug resistance; have created a major environmental concern. The aim of this study was to evaluate UV/peroxymonosulfate (UV/PMS) process efficiency in the removal of cefexime antibiotic from aqueous solution. Materials and Methods: This experimental lab...
متن کاملSynthesis and Characterization of CdS/g-C3N4/rGO Composite and Evaluation of its Photocatalytic Performance from Kinetics Perspective
In this research, CdS/g-C3N4 /rGO ternary composite was prepared by hydrothermal method and characterized using various techniques including X-ray diffraction (XRD), field emission-scanning electron microscopy (FE-SEM) and UV-Visible spectrophotometer. The photocatalytic activity of the prepared composite was evaluated from kinetics perspective by studying the removal of ciprofloxacin antibioti...
متن کاملEvaluation of the efficiency of a photocatalytic process using the magnetic nanocatalyst (Fe3O4@SiO2@TiO2) in the removal of ceftriaxone from aqueous solutions
Background & Objectives: Ceftriaxone is an antibiotic which is extensively used to treat a number of various infections. It is mainly accumulated in water and sewage resulting in the environmental and health problems. This study is centered on the evaluation of the efficiency of a photocatalytic process using Fe3O4@SiO2@TiO2 in the removal of ceftriaxone from aqueous solutions. Methods: This r...
متن کاملThe effects of operating factors on the removal of total ammonia nitrogen and florfenicol antibiotic from synthetic trout fish farm wastewater through nanofiltration
An aquaculture system can be a potentially significant source of antibacterial compounds and ammonia in an aquatic environment. In this study, the removal of total ammonia nitrogen and florfenicol antibiotic from synthetic aqueous wastewater was assessed by applying a commercial TFC (thin film composite) polyamide nanofilter. The effects of pH (6.5-8.5), pressure (4-10 bar), concentration of to...
متن کاملPhotodegradation of the Antibiotic Penicillin G in the Aqueous Solution using UV-A Radiation
Background and purpose: Highly consumption of antibiotics and their entrance into the environment has increased concerns all over the world. These compounds enter to the environment through an incomplete metabolism and a considerable amount of them cannot be removed using usual waste filtration systems. Therefore, the present study aimed to investigate the feasibility of using ultraviolet radia...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of clinical microbiology
دوره 15 2 شماره
صفحات -
تاریخ انتشار 1982