Optimization of a flow injection system with amperometric detection for arsenic determination.
نویسندگان
چکیده
A selective and sensitive analytical procedure for rapid arsenic determination by gas-diffusion flow injection analysis with amperometric detection was developed. The method is based on the arsenite reduction by NaBH(4). Derived arsine diffuses through a PTF membrane into the acceptor flow stream and is amperometrically determined on a platinum working electrode. The limit of detection (3 sigma) at room temperature was 5 microg/dm(3) of As(III). The relative standard deviation for a 1 mg/dm(3) As(III) standard was 1.96% for six repetitive injections. Arsenic(V) was determined after its prereduction with potassium iodide. Arsenic determination was not interferred with by 1 mg/dm(3) Sb(III), 5 mg/dm(3) Sn(II), 10 mg/dm(3) Se(IV), 1 mg/dm(3) As(V), 1 mg/dm(3) hydrasine, 1 mg/dm(3) Fe(II) or 0.5 mg/dm(3) Fe(III) solution. The throughput of this method was 60 analyses per hour. This method was successfully applied to arsenic determination in some power plant waste water samples.
منابع مشابه
Flow-Injection Amperometric Determination of Ascorbic Acid Using a Graphite-Epoxy Composite Electrode Modified with Cobalt Phthalocyanine
A flow injection method is reported for the determination of ascorbic acid based on amperometric detection, using a cobalt(II) phthalocyanine (CoPc) modified graphite-epoxy electrode. The amperometric respons was evaluated with regard to pH, ionic strength of the electrolyte, flow rate of the carrier solution, injected sample volume and conditioning time of the electrode. The limit of detec...
متن کاملFlow Injection Spectrophotometric Determination of Sulphide by Catalytic Reduction of Toluidine Blue
Sulphide was determined spectrophotometrically at 628 nm and pH 6.7 based on its catalytic reduction of toluidine blue in the presence of Se(IV) using a flow injection system. After optimization of the measuring conditions the calibration curve was found linear up to 25 mg/mL and the detection limit was 0.3 mg/mL (30 mL injections). The ...
متن کاملFLOW INJECTIOW DETERMINATION OF FLUORIDE BY MURTN-ALUMINUM REAGEM WITH SPECTROEUORIMIETRIC DETECTION
A flow injection system is reported for the determination of fluoride based on its effects on the fluorescence intensity of Al-morin complex at pH 3.0 in ethanol-warn mixture. The effect of important parameters such as excitation and emission wavelengths, pH, reagents concenkations, flow rate of the carrier stream, sample injection volume, time of measurepent and interferences are reported. ...
متن کاملDETERMINATION OF AMOXYCYLLIN AND CLAVULANIC ACID IN PHARMACEUTICAL DOSAGE FORMS BY HPLC WITH AMPEROMETRIC DETECTION
A simple and sensitive high performance liquid chromatographic method with electrochemical detection is described for the quantitative determination of the amoxycillin and clavulanic acid in pharmaceutical dosage forms. Separation of sample components occurs on a reversed phase C18 column with a mobile phase consisting of methanol-water-phosphate buffer. For the amperometric detection, the pote...
متن کاملRapid High Performance Liquid Chromatographic Method for Determination of Clarithromycin in Human Plasma Using Amperometric Detection: Application in Pharmacokinetic and Bioequivalence Studies
A rapid, sensitive and reproducible HPLC method using amperometric detector was developed and validated for the analysis of clarithromycin in human plasma. The separation was achieved on a monolithic silica column (MZ- C8 125×4.0 mm) using acetonitrile- methanol-potassium dihydrogen phosphate buffer (40:6:54,v/v), with pH of 7.5, as the mobile phase at a flow rate of 1.5 mL/min. The assay enabl...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Analytical sciences : the international journal of the Japan Society for Analytical Chemistry
دوره 24 7 شماره