Complexes of arsenic compounds and glutathione are believed to play an essential part in the metabolism and transport of inorganic arsenic and its methylated species. Up to now, the evidence of their presence is mostly indirect. We studied the stability and chromatographic behaviour of glutathione complexes with trivalent arsenic: i.e. As(GS)3, MA (GS)2 and DMA (GS) under different conditions. Standard ion chromatography using PRP X-100 and carbonate or formic acid buffer disintegrated the complexes, while all three complexes are stable and separable by reversed phase chromatography (0.1% formic acid/acetonitrile gradient). As(GS)3 and MA(GS)2 were more stable than DMA (GS), which even under optimal conditions tended to degrade on the column at 25 uC. Chromatography at 6 uC can retain the integrity of the samples. These results shed more light on the interpretation of a vast number of previously published arsenic speciation studies, which have used chromatographic separation techniques with the assumption that the integrity of the arsenic species is guaranteed.
منابع مشابه
Methylated Trivalent Arsenic-Glutathione Complexes are More Stable than their Arsenite Analog
The trivalent arsenic glutathione complexes arsenic triglutathione, methylarsonous diglutathione, and dimethylarsinous glutathione are key intermediates in the mammalian metabolism of arsenite and possibly represent the arsenic species that are transported from the liver to the kidney for urinary excretion. Despite this, the comparative stability of the arsenic-sulfur bonds in these complexes h...
متن کاملIMPROVED CHROMATOGRAPHIC METHOD FOR DETERMINATION OF SODIUM DICLOFENAC IN INJECTABLE SOLUTION AND PREDICTION OF CHEMICAL STABILITY
Two modified methods for assaying sodium diclofenac were developed by GC and HPLC. Diclofenac was converted into methyl ester derivative by methyl iodide in acetone. The ester was extract and subjected to GLC with flame ionization detector. %5 SE-30/chrom W-HP (80-100 mesh) was used as a column in GC. For reversed phase HPLC, the mobile phase was methanol and water (55-45). The separation was p...
متن کاملMetal-Ion-Coordinating Properties of Various Amino Acids, Investigation of the Essential Function in Biological Systems regarding to their Nano-Structure
The acidity constants of some amino acids (Am) were determined by potentiometric pH titration. The stability constants of the 1:1 complexes formed between M2+: Ca2+, Mg2+, Mn2+, Co2+, Ni2+, Cu2+ or Zn2+ and Am2-, were determined by potentiometric pH titration in aqueous solution (I = 0.1 M, NaNO3, 25°C). The order of the stability constants was reported. It is shown that the stability of the bi...
متن کاملMetal-Ion-Coordinating Properties of Various Amino Acids, Investigation of the Essential Function in Biological Systems regarding to their Nano-Structure
The acidity constants of some amino acids (Am) were determined by potentiometric pH titration. The stability constants of the 1:1 complexes formed between M2+: Ca2+, Mg2+, Mn2+, Co2+, Ni2+, Cu2+ or Zn2+ and Am2-, were determined by potentiometric pH titration in aqueous solution (I = 0.1 M, NaNO3, 25°C). The order of the stability constants was reported. It is shown that the stability of the bi...
متن کاملA stability-Indicating HPLC Method for Simultaneous Determination of Creatine Phosphate Sodium and its Related Substances in Pharmaceutical Formulation
The objective of the study was to develop a simple, specific and stability-indicating HPLC method for the simultaneous determination of creatine phosphate sodium (CPS) and its related substances in pharmaceutical formulation. Separation of creatine phosphate sodium from its major process impurities and degradation products was achieved on a Hypersil BDS C18 column (250 × 4.6 mm, 5 μm) with an a...