Accelerated C-Arm Reconstruction by Out-of-Projection Prediction

نویسندگان

  • Hannes G. Hofmann
  • Benjamin Keck
  • Joachim Hornegger
چکیده

3D image reconstruction from C-arm projections is a computationally demanding task. However, for interventional procedures a fast reconstruction is desirable. We present a method to reduce the number of actually back-projected voxels and ultimately the processing time by 20–30% without affecting image quality. The proposed method detects and skips subvolumes that are not visible in the current view. It works with projection matrices and is thus capable of handling arbitrary geometries. It can easily be incorporated into existing algorithms and is also suitable for the back-projection step of iterative algorithms.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Nipple Reconstruction Using the C-V Flap Technique: Long-Term Outcomes and Patient Satisfaction

BACKGROUND Nipple creation using the C-V flap technique is often the final step in breast reconstruction. The aim of this study was to subjectively and objectively assess the cosmetic outcomes and satisfaction of patients undergoing C-V flap nipple reconstruction. METHODS Subjective assessments of patient satisfaction with the neo-nipple were recorded by visual analogue scoring (VAS; 0...

متن کامل

Cardiac C-Arm CT SNR Enhancement by Combining Multiple Retrospectively Motion Corrected FDK-Like Reconstructions

Cardiac C-arm CT is a promising technique that enables 3D cardiac image acquisition and real-time fluoroscopy on the same system. Retrospective ECG gating techniques have already been adapted from clinical cardiac CT that allow 3D reconstruction using retrospectively gated projection images of a multi-sweep C-arm CT scan according to the desired cardiac phase. However, it is known that retrospe...

متن کامل

Utilization of an optimum low-pass filter during filtered back-projection in the reconstruction of single photon emission computed tomography images of small structures

Introduction:Low-pass filters eliminate noise, and accordingly improve the quality of filtered back-projection (FBP) in the reconstruction of single photon emission computed tomography (SPECT) images. This study aimed at selection of an optimum low-pass filter for FBP reconstruction of SPECT images of small structures. Material and Methods:Sp...

متن کامل

Comparing IDREAM as an Iterative Reconstruction Algorithm against In Filtered Back Projection in Computed Tomography

Introduction: Recent studies of Computed Tomography (CT) conducted on patient dose reduction have recommended using an iterative reconstruction algorithm and mA (mili-Ampere) dose modulation. The current study aimed to evaluate Iterative Dose Reduction Algorithm (IDREAM) as an iterative reconstruction algorithm. Material and Methods: Two CT p...

متن کامل

Cardiac C-Arm CT: Image-based Gating

Image guidance during cardiac interventional procedures (IP) using cardiac C-arm CT systems is desirable for many procedures. Applying the concept of retrospective electrocardiogram gating (ECG) to the acquisition of multiple, ECG-triggered rotational acquisitions using a C-arm system allows the 3D+t reconstruction of the heart. The process of retrospective gating is a crucial component of 3-D ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010