Effect of follower load on motion and stiffness of the human thoracic spine with intact rib cage.
نویسندگان
چکیده
Researchers have reported on the importance of the rib cage in maintaining mechanical stability in the thoracic spine and on the validity of a compressive follower preload. However, dynamic mechanical testing using both the rib cage and follower load has never been studied. An in vitro biomechanical study of human cadaveric thoracic specimens with rib cage intact in lateral bending, flexion/extension, and axial rotation under varying compressive follower preloads was performed. The objective was to characterize the motion and stiffness of the thoracic spine with intact rib cage and follower preload. The hypotheses tested for all modes of bending were (i) range of motion, elastic zone, and neutral zone will be reduced with a follower load, and (ii) neutral and elastic zone stiffness will be increased with a follower load. Eight human cadaveric thoracic spine specimen (T1-T12) with intact rib cage were subjected to 5Nm pure moments in lateral bending, flexion/extension, and axial rotation under follower loads of 0-400N. Range of motion, elastic and neutral zones, and elastic and neutral zone stiffness values were calculated for functional spinal units and segments within the entire thoracic section. Combined segmental range of motion decreased by an average of 34% with follower load for every mode. Application of a follower load with intact rib cage impacts the motion and stiffness of the human cadaveric thoracic spine. Researchers should consider including both aspects to better represent the physiologic implications of human motion and improve clinically relevant biomechanical thoracic spine testing.
منابع مشابه
The rib cage stabilizes the human thoracic spine: An in vitro study using stepwise reduction of rib cage structures
The stabilizing effect of the rib cage on the human thoracic spine is still not sufficiently analyzed. For a better understanding of this effect as well as the calibration and validation of numerical models of the thoracic spine, experimental biomechanics data is required. This study aimed to determine (1) the stabilizing effect of the single rib cage structures on the human thoracic spine as w...
متن کاملEffects of surgical joint destabilization on load sharing between ligamentous structures in the thoracic spine: a finite element investigation.
BACKGROUND In vitro investigations have demonstrated the importance of the ribcage in stabilizing the thoracic spine. Surgical alterations of the ribcage may change load-sharing patterns in the thoracic spine. Computer models are used in this study to explore the effect of surgical disruption of the rib-vertebrae connections on ligament load-sharing in the thoracic spine. METHODS A finite ele...
متن کاملRib head disarticulation for multilevel transpedicular thoracic corpectomies and expandable cage reconstruction.
Traditional posterior approaches to the thoracic spine are done with either costo-transversectomy, lateral extracavitary approaches, or transpedicular approaches. The transpedicular approach is the only one that preserves the rib head. However, placing an expandable cage with this rib head intact poses special challenges because of the narrow corridor defined by the rib head and the spinal cord...
متن کاملVEPTR Treating three-dimensional thoracic deformity of early onset scoliosis
The Synthes Spine Vertical Expandable Prosthetic Titanium Rib (VEPTR) allows new growth sparing surgical procedures for treatment of spine deformity in early childhood. The prime FDA indication for its use is the presence of thoracic insufficiency syndrome [1], which is the inability of the thorax to support normal respiration or lung growth. This syndrome is most often due to three-dimensional...
متن کاملTHE EFFECTS OF ANTERIOR DISCECTOMY AND INTERPOSITION AL IMPLANT UPON LUMBAR MOTION SEGMENT STABILITY
The cadaver spine motion segment behavior under torsional load was evaluated with the disc intact, with partial anterior discectomy and with spacer insertion. The results of this study explain how anterior lumbar discectomy and interbody fusion (ALIF) affects the torsional stability of the motion segment. The pseudarthrosis rate of the anterior lumbar discectomy and interbody fusion (ALIF)...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of biomechanics
دوره 49 14 شماره
صفحات -
تاریخ انتشار 2016