Minimally-invasive glaucoma surgeries (MIGS) for open angle glaucoma: A systematic review and meta-analysis

نویسندگان

  • Carlo Lavia
  • Laura Dallorto
  • Milena Maule
  • Manuela Ceccarelli
  • Antonio Maria Fea
چکیده

BACKGROUND MIGS have been developed as a surgical alternative for glaucomatous patients. PURPOSE To analyze the change in intraocular pressure (IOP) and glaucoma medications using different MIGS devices (Trabectome, iStent, Excimer Laser Trabeculotomy (ELT), iStent Supra, CyPass, XEN, Hydrus, Fugo Blade, Ab interno canaloplasty, Goniscopy-assisted transluminal trabeculotomy) as a solo procedure or in association with phacoemulsification. METHODS Randomized control trials (RCT) and non-RCT (non randomized comparative studies, NRS, and before-after studies) were included. Studies with at least one year of follow-up in patients affected by primary open angle glaucoma, pseudoexfoliative glaucoma or pigmentary glaucoma were considered. Risk of Bias assessment was performed using the Cochrane Risk of Bias and the ROBINS-I tools. The main outcome was the effect of MIGS devices compared to medical therapy, cataract surgery, other glaucoma surgeries and other MIGS on both IOP and use of glaucoma medications 12 months after surgery. Outcomes measures were the mean difference in the change of IOP and glaucoma medication compared to baseline at one and two years and all ocular adverse events. The current meta-analysis is registered on PROSPERO (reference n° CRD42016037280). RESULTS Over a total of 3,069 studies, nine RCT and 21 case series with a total of 2.928 eyes were included. Main concerns about risk of bias in RCTs were lack of blinding, allocation concealment and attrition bias while in non-RCTs they were represented by patients' selection, masking of participants and co-intervention management. Limited evidence was found based on both RCTs and non RCTs that compared MIGS surgery with medical therapy or other MIGS. In before-after series, MIGS surgery seemed effective in lowering both IOP and glaucoma drug use. MIGS showed a good safety profile: IOP spikes were the most frequent complications and no cases of infection or BCVA loss due to glaucoma were reported. CONCLUSIONS Although MIGS seem efficient in the reduction of the IOP and glaucoma medication and show good safety profile, this evidence is mainly derived from non-comparative studies and further, good quality RCTs are warranted.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

When Is Evidence Enough Evidence? A Systematic Review and Meta-Analysis of the Trabectome as a Solo Procedure in Patients with Primary Open-Angle Glaucoma

The purpose of this systematic review and meta-analysis was to examine the availability of evidence for one of the earliest available minimally invasive glaucoma surgery (MIGS) procedures, the Trabectome. Various databases were searched up to December 20, 2016, for any published studies assessing the use of the Trabectome as a solo procedure in patients with primary open-angle glaucoma (POAG). ...

متن کامل

Update on Minimally Invasive Glaucoma Surgery (MIGS) and New Implants

Traditional glaucoma surgery has been challenged by the advent of innovative techniques and new implants in the past few years. There is an increasing demand for safer glaucoma surgery offering patients a timely surgical solution in reducing intraocular pressure (IOP) and improving their quality of life. The new procedures and devices aim to lower IOP with a higher safety profile than fistulati...

متن کامل

The New Era of Glaucoma Micro-stent Surgery

Minimally invasive glaucoma surgery (MIGS) has been gaining popularity over the last decade. Although there is no strict definition for MIGS, all the new procedures share the common theme of intraocular pressure reduction with minimal tissue destruction, short surgical time, simple instrumentation and fast postoperative recovery. The use of glaucoma drainage implants has long been the tradition...

متن کامل

iStent® Trabecular Microbypass Stent: An Update

Due to the high rates of complications and failure experienced with current glaucoma procedures, there is a continuous search for a safer and more effective glaucoma surgery. A new class of procedures termed minimally invasive glaucoma surgeries (MIGS) aim to fill this void by offering an alternative method of IOP reduction associated with markedly reduced complication rates and shorter recover...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2017