Superior early diagnostic performance of a sensitive cardiac troponin assay as compared to a standard troponin test in the diagnosis of acute myocardial infarction.

نویسندگان

  • Radosław Pracoń
  • Mariusz Kruk
  • Barbara Jakubczak
  • Marcin Demkow
  • Zofia T Bilińska
چکیده

BACKGROUND New generation cardiac troponin assays have sufficient precision to detect and quantify plasma troponin concentrations below the lower threshold of detection of the currently employed troponin tests. However, diagnostic performance of the newer generation assays in daily clinical practice is not well established. AIM To evaluate the diagnostic performance of a sensitive assay as compared to a standard assay in a single reading at admission in the diagnosis of acute myocardial infarction (AMI) in patients presenting to the Emergency Department with chest pain. METHODS The study comprised 187 consecutive patients admitted to the Institute of Cardiology in Warsaw in June and July 2010 with chest pain in whom the attending physician ordered troponin assay to rule AMI in or out. In all of these patients, in addition to the standard Dimension Flex Troponin I (Siemens Healthcare Diagnostics, Inc.) the sensitive Architect Stat Troponin I (Abbott Diagnostics) test was assayed. The triage of patients as well as all diagnostic and treatment decisions were left to the discretion of the attending physician who was blinded to the sensitive troponin test readings. The final diagnosis was adjudicated by a team of two cardiologists on the basis of all the available medical records except for sensitive troponin test results. RESULTS Mean age of the study cohort (n = 187) was 64.3 ± 13.9 years and 119 (63.6%) were males. The final diagnosis of AMI was adjudicated in 84 (44.9%) patients (mean age 67.5 ± 12.9 years; 119 [63.6%] males). Receiver operating characteristic (ROC) analysis showed greater area under the curve (AUC) for the sensitive cardiac troponin assay compared to the standard assay (AUC = 0.916, 95% CI = 0.866-0.951 vs AUC = 0.863, 95% CI = 0.806-0.909, respectively; p = 0.02) in a single reading at admission. Sensitive assay was characterised by higher sensitivity (87%), specificity (88%), positive (86%) and negative (89%) predictive values in the detection of AMI compared to the standard troponin test (82%, 81%, 78%, and 85% respectively). CONCLUSIONS The newer generation sensitive cardiac troponin assay presented superior diagnostic accuracy in the diagnosis of AMI compared to the standard troponin test in a single reading at admission with improved sensitivity and specificity. The sensitive troponin assay has the potential to improve early detection and/or exclusion of AMI.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cardiac enzyme in emergency medicine

Objective: Acute chest pain is an important and frequently occurring symptom in patients. Chest pain is often a sign of ischemic heart disease. Chest pain due to suspected Acute Coronary Syndrome (ACS) is responsible for a large and ijncreasing number of hospital attendances and admissions. Current practice for suspected ACS involves troponin testing 10–12 hours after symptom o...

متن کامل

An Aptamer-based Biosensor for Troponin I Detection in Diagnosis of Myocardial Infarction

Background: Acute myocardial infarction (MI) accounts for one third of deaths. Cardiac troponin I (TnI) is a reliable biomarker of cardiac muscle tissue injury and is employed in the early diagnosis of MI.Objectives: In this study, a molecular method is introduced to early diagnosis of MI by rapid detection of TnI.Materials and Methods: The detection method was based on electrochemical aptasens...

متن کامل

The most sensitive double-marker method of cardiac isoenzymes of creatinine kinase, troponin I, and myoglobin in different time periods for diagnosing acute myocardial infarction

  Purpose: Myocardial infarction is among the most common diagnoses in patients admitted   to hospitals in western countries, and its rapid diagnosis is of utmost importance. This study   was conducted to determine the most sensitive double-marker cardiac isoenzyme of creatinine   kinase, troponin I, and myoglobin for diagnosing acute myocardial infarction.   Materials and Methods: This was an ...

متن کامل

study of platelet parameters in the patients with acute myocardial infarction referred to Ali Shariati Hospital in 2018

Introdution: The rapid and accurate diagnosis of acute myocardial infarction is essential for effective treatment. Recently, troponin has been introduced as a biochemical marker for early diagnosis of acute myocardial infarction. Platelet parameters (P-LCR, MPV, PDW) play a key role in the pathophysiology of acute coronary syndrome. The aim of this study was to evaluate platelet indexes in the ...

متن کامل

Early diagnosis of myocardial infarction with sensitive cardiac troponin assays.

BACKGROUND The rapid and reliable diagnosis of acute myocardial infarction is a major unmet clinical need. METHODS We conducted a multicenter study to examine the diagnostic accuracy of new, sensitive cardiac troponin assays performed on blood samples obtained in the emergency department from 718 consecutive patients who presented with symptoms suggestive of acute myocardial infarction. Cardi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Kardiologia polska

دوره 70 2  شماره 

صفحات  -

تاریخ انتشار 2012