Resolution studies with the DATURA beam telescope
نویسنده
چکیده
Detailed studies of the resolution of a EUDET-type beam telescope are carried out using the DATURA beam telescope as an example. The EUDET-type beam telescopes make use of CMOS MIMOSA 26 pixel detectors for particle tracking allowing for precise characterisation of particle sensing devices. A profound understanding of the performance of the beam telescope as a whole is obtained by a detailed characterisation of the sensors themselves. The differential intrinsic resolution as measured in a MIMOSA 26 sensor is extracted using an iterative pull method and various quantities that depend on the size of the cluster are discussed: the residual distribution, the intra-pixel residual-width distribution and the intra-pixel density distribution of track incident positions.
منابع مشابه
The Synthesis Telescope at the Dominion Radio Astrophysical Observatory
We describe an aperture synthesis radio telescope optimized for studies of the Galactic interstellar medium (ISM), providing the ability to image extended structures with high angular resolution over wide fields. The telescope produces images of atomic hydrogen emission using the 21-cm H i spectral line, and, simultaneously, continuum emission in two bands centred at 1420MHz and 408MHz, includi...
متن کاملResults from the EUDET telescope with high resolution planes
A high resolution (σ < 3μm) beam telescope based on monolithic active pixel sensors is being developed within the EUDET collaboration. EUDET is a coordinated detector R&D programme for the future International Linear Collider providing test beam infrastructure to detector R&D groups. The telescope consists of six sensor planes with a pixel pitch of either 30 or 10 μm and can be operated inside ...
متن کاملPerformance of myocardial perfusion imaging using multi-focus fan beam collimator with resolution recovery reconstruction in a comparison with conventional SPECT
Objective: IQSPECT is an advanced high-speed SPECT modality for performing myocardial perfusion imaging (MPI), which uses a multi-focus fan beam collimator with resolution recovery reconstruction. The aim of this study was to compare IQSPECT compared with conventional SPECT interms of performance based on standard clinical protocols. In addition, we examined the concordance between convention...
متن کاملUniversit . . at Bonn Physikalisches Institut Performance of a Beam Telescope Using Double Sided Silicon Microstrip Detectors ?
A beam telescope consisting of four double sided, DC coupled microstrip detectors with VLSI readout electronics has been built and tested in a 70 GeV ? beam at CERN. A signal to noise ratio of 53:1 and a spatial resolution of 2.7m (junction side) and 4.8m (ohmic side) have been observed on the best detectors. A telescope performance for a particle track of xy = 2 ? 3 m and slope = 2 ? 3 rad on ...
متن کاملThree-beam Doppler optical coherence tomography using a facet prism telescope and MEMS mirror for improved transversal resolution
An improved three-beam Doppler optical coherence tomography system was developed. It utilizes a custom-made three-facet prism telescope to improve the transversal resolution at the sample. Furthermore, a two-axis gimbal-less MEMS mirror is used to minimize off-pivot beam movement at the pupil of the eye, enabling circular scanning for in vivo retinal measurements. We demonstrate the system's ab...
متن کامل