Coronary vein balloon angioplasty for left ventricular pacemaker lead implantation.

نویسندگان

  • Bert Hansky
  • Barbara Lamp
  • Kazutomo Minami
  • Johannes Heintze
  • Leon Krater
  • Dieter Horstkotte
  • Reiner Koerfer
  • Jürgen Vogt
چکیده

OBJECTIVES Retrospective analysis of five cases of coronary vein balloon angioplasty performed to allow insertion of left ventricular pacing leads. BACKGROUND Coronary vein stenoses or an insufficient vessel caliber can preclude transvenous placement of coronary vein leads. METHODS We compared our total patient population (n = 218), in whom we implanted coronary vein leads, to those five patients who required coronary vein angioplasty to allow lead placement. Standard over-the-wire coronary artery balloon angioplasty catheters were used to dilate the vessel to 2.5 mm (n = 3) or 3.5 mm (n = 2). RESULTS Transvenous lead placement succeeds in >99% of patients. Four cases of target vein stenoses and one case of a vein of insufficient caliber were successfully treated by balloon angioplasty. There were no complications. CONCLUSIONS Coronary vein angioplasty is an effective and safe technique to permit transvenous left ventricular pacing lead insertion in cases of target vein stenoses or insufficient target vein caliber.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

ACP Journal Club. Nonemergency PCI without onsite cardiac surgery was noninferior to PCI with onsite services for MACE.

Patients: 3691 patients (mean age 65 y, 68% men) who had diagnostic catheterization for coronary artery disease in a hospital without onsite cardiac surgery services. Exclusion criteria included left ventricular ejection fraction < 20% and target lesions with ≥ 1 of the following: saphenous vein graft location, vessel serving the only viable myocardium, unprotected left main coronary artery ste...

متن کامل

Retaining of PTCA guide wire in the left ventricular lead and subsequent application of epicardial electrode when CRT-D implantation in a patient with severe heart failure and persistent left superior vena cava: a case report.

OBJECTIVE One patient with severe heart failure (LV 92 mm, EF 28%) was treated by cardiac resynchronization therapy (CRT). METHOD During the operation, it was found that double superior vena cava coexisted, and selective coronary venography cannot clearly show every branch. It was difficult to push ventriculus sinister electrode to sideward vein, so the electrode was released to far end of fr...

متن کامل

MRI for Visualization of Coronary Vein Branches Used for Pacemaker Lead Implantation

Purpose Approximately one third of all patients who undergo Cardiac Resynchronization Therapy (CRT) using a biventricular pacemaker do not benefit from the procedure [1]. Studies have shown that the location of the left ventricular (LV) lead plays an important role in dictating whether patients benefit from the procedure [2,3]. Patients benefit most when the LV lead is placed in the latest cont...

متن کامل

Hyperemic coronary flow after optimized intravascular ultrasound-guided balloon angioplasty and stent implantation.

OBJECTIVES This study evaluated the acute physiological gain of adjunctive intravascular ultrasound (IVUS) guided balloon angioplasty and stent implantation. BACKGROUND Recent studies indicate safe coronary luminal enlargement and "stent-like" long-term outcomes using upsized balloons guided by IVUS. METHODS After angiographically guided balloon angioplasty in 20 patients with 1-vessel dise...

متن کامل

Immediate and long-term effect of balloon angioplasty or stent implantation on the absolute and relative coronary blood flow velocity reserve.

BACKGROUND There is controversy regarding the immediate and long-term effects of PTCA on the coronary flow reserve. METHODS AND RESULTS A total of 54 patients with 1-vessel disease and normal left ventricular function were studied after balloon angioplasty (n=34) or stent implantation (n=20). Distal coronary blood flow velocity reserve (CFR) was defined as the ratio of adenosine-induced hyper...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the American College of Cardiology

دوره 40 12  شماره 

صفحات  -

تاریخ انتشار 2002