A Novel Spinal Implant for Fusionless Scoliosis Correction: A Biomechanical Analysis of the Motion Preserving Properties of a Posterior Periapical Concave Distraction Device

نویسندگان

  • Roderick M. Holewijn
  • Marinus de Kleuver
  • Albert J. van der Veen
  • Kaj S. Emanuel
  • Arno Bisschop
  • Agnita Stadhouder
  • Barend J. van Royen
  • Idsart Kingma
چکیده

STUDY DESIGN Biomechanical study. OBJECTIVE Recently, a posterior concave periapical distraction device for fusionless scoliosis correction was introduced. The goal of this study was to quantify the effect of the periapical distraction device on spinal range of motion (ROM) in comparison with traditional rigid pedicle screw-rod instrumentation. METHODS Using a spinal motion simulator, 6 human spines were loaded with 4 N m and 6 porcine spines with 2 N m to induce flexion-extension (FE), lateral bending (LB), and axial rotation (AR). ROM was measured in 3 conditions: untreated, periapical distraction device, and rigid pedicle screw-rod instrumentation. RESULTS The periapical distraction device caused a significant (P < .05) decrease in ROM of FE (human, -40.0% and porcine, -55.9%) and LB (human, -18.2% and porcine, -17.9%) as compared to the untreated spine, while ROM of AR remained unaffected. In comparison, rigid instrumentation caused a significantly (P < .05) larger decrease in ROM of FE (human, -80.9% and porcine, -94.0%), LB (human, -75.0% and porcine, -92.2%), and AR (human, -71.3% and porcine, -86.9%). CONCLUSIONS Although no destructive forces were applied, no device failures were observed. Spinal ROM was significantly less constrained by the periapical distraction device compared to rigid pedicle screw-rod instrumentation. Therefore, provided that scoliosis correction is achieved, a more physiological spinal motion is expected after scoliosis correction with the posterior concave periapical distraction device.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fusionless Correction of Moderate Adolescent Idiopathic Scoliosis with a New Minimally Invasive Dynamic Implant (ApiFix®) and Postoperative Schroth Scoliosis Specific Exercises-Case Series

The standard surgical management of AIS is spinal fusion. Nonfusion solutions for addressing moderate AIS curves are desirable. ApiFix® is a new posterior dynamic device consisting of an expandable ratcheting rod anchored by two pedicle screws to the concave side of the scoliotic spine. It was designed to address single, moderate Lenke type 1 or 5 curves. Surgery is performed without the additi...

متن کامل

Biomechanics of Two Fusionless Scoliosis Correction Techniques- Rigid Staple vs. Flexible Tether

INTRODUCTION: Currently, there are two clinically relevant, fusionless surgical treatments that utilize growth modulation for scoliosis deformity correction. The first treatment incorporates the use of two parallel Nitinol staples and the second treatment uses a flexible, ultra-high molecular-weight polyethylene (UHMWPE) tether. Both techniques have been shown to successfully modulate spinal gr...

متن کامل

Three-dimensional analysis of 2 fusionless scoliosis treatments: a flexible ligament tether versus a rigid-shape memory alloy staple.

STUDY DESIGN Experimental scoliosis was created and subsequently corrected in goats. The 3-dimensional (3-D) effects of the treatments were analyzed. OBJECTIVE To analyze the 3-D effect of 2 different fusionless scoliosis treatment techniques on an experimental idiopathic-type scoliosis using plain radiographs and computerized tomography. SUMMARY OF BACKGROUND DATA Scoliosis is a complex 3-...

متن کامل

Biomechanical effect of pedicle screw distribution in AIS instrumentation using a segmental translation technique: computer modeling and simulation

BACKGROUND Efforts to select the appropriate number of implants in adolescent idiopathic scoliosis (AIS) instrumentation are hampered by a lack of biomechanical studies. The objective was to biomechanically evaluate screw density at different regions in the curve for AIS correction to test the hypothesis that alternative screw patterns do not compromise anticipated correction in AIS when using ...

متن کامل

مقایسه نتایج کوتاه مدت و بلند مدت فیوژن ستون مهره‌ها با و بدون وسیله‌گذاری خلفی در درمان اسکولیوز مادرزادی

Background: Congenital scoliosis is a developmental disorder defined as a lateral curvature of the spine. Its progressive trend and complications, such as cosmetic problems, pain and pulmonary symptoms, have put scoliosis as an important skeletal deformity that should be corrected. One of the currently accepted methods of treatment is posterior spinal fusion (PSF) that may be performed with or ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 7  شماره 

صفحات  -

تاریخ انتشار 2017