Calculation of equivalent dose for the lens of the eye in a positron field using EGS5
نویسندگان
چکیده
The equivalent dose rate per positron fluence for the human eye lens is calculated using a Monte Carlo simulation code, EGS5, with two mathematical models (a computational head voxel phantom and a simple eye model). The eye lens doses for medical staff and carers as received from a radiopharmaceutical such as F-FDG, which is used in PET examinations, when spilled on the floor, and from positrons passing through a thin injection tube are calculated using a simple eye model. At energies less than 1 MeV, the equivalent dose for the eye lens per electron and positron fluence as calculated using the simple eye model was a maximum of three orders of magnitude lower than that for the head voxel phantom. These values for the simple eye model were equal to the calculation results obtained using the eye lens model in ICRP Publication 116 and those reported in past studies. The eye lens dose rates from the point and tube sources of F-FDG as calculated using our simple eye model are about 0.57 and 0.37 Sv min MBq at 5 cm, respectively. The doses at 10 cm were one-third to half of those at 5 cm.
منابع مشابه
Measurement of the Adsorbed Radiation Dose to Eyelens During CT Scan and Radiotherapy of Nasopharynx Cancer
Introduction: The study of the cause of death during the last few decades has shown that death due to infectious diseases has been declining and has been rising due to noninvasive diseases, especially cancers and accidents. Cancer is considered as one of the fatal diseases, and every year, more than 10.9 million people worldwide are diagnosed with the disease. Mater...
متن کاملDevelopment of an Accommodation-Dependent Eye Model and Studying the Effects of Accommodation on Electron and Proton Dose Conversion Coefficients
Introduction International Commission on Radiological Protection (ICRP) has provided a comprehensive discussion on threshold dose for radiation-induced cataract in ICRP publication 116. Accordingly, various parts of the eye lens have different radio-sensitivities. Recently, some studies have been performed to develop a realistic eye model with the aim of providing accurate estimation of fluence...
متن کاملCalculation of total dose and dose equivalent distribution in the treatment of lung cancer using MR-guided carbon therapy
Nowadays, in order to improve the accuracy of treatment in radiation therapy, there are many attempts to use magnetic resonance imaging (MRI) due to the advantages of excellent soft tissue contrast and ultra-fast pulse sequences. On the other hand, carbon-ion radiation therapy is developing rapidly due to the benefits of greater relative biological effectiveness (RBE) and the application in the...
متن کاملEvaluation of Occupational Radiation Status and Validity of Individual Dose and Eye Lens Assessment Using Single Film Dosimeter for Angiographic Staff in Iran
Background and Aim: In angiography, the lens of the eye may be exposed to radiation and cause cataracts. In Iran, at present, only a single film dosimeter is used under the lead-apron to evaluate individual doses. The aim of this study was to investigate the status of occupational radiation as well as the validity of measuring the dose of the whole body of individuals and eye lenses using a sin...
متن کاملAssessing the image quality and eye lens dose reduction using bismuth shielding in computed tomography of brain
Background: Epidemiological studies show that computed tomography (CT) is one of the main sources of ionizing radiations. Shielding of radiosensitive organs is one of the dose reduction methods. This study aimed to assess the eye lens dose reduction and image quality resulting from the use of radio-protective bismuth shield in brain CT imaging. Methods: Bismut...