Evaluation of tolerance to ambulatory blood pressure monitoring

نویسندگان

  • Gino Iannucci
  • Luigi Petramala
  • Giuseppe La Torre
  • Barbara Barbaro
  • Clara Balsano
  • Pietro Giacomo Curatulo
  • Francesco Amadei
  • Marino Paroli
  • Antonio Concistrè
  • Claudio Letizia
چکیده

Ambulatory blood pressure monitoring (ABPM) is a helpful tool to comprehensively identify and diagnose arterial hypertension. Moreover, it allows to better identify alterations in the circadian BP profile, as the nocturnal "nondipping" status, characterized by a lack of the physiological 10% night BP reduction and associated with a greater risk of target organ damage. However, ABPM has some limitations such as restricted availability, discomfort, particularly at night, cost implications, and reproducibility.Aim of the study was evaluate if the "nondipping" phenomenon may be related to low degree of tolerance to ABPM. Additionally, to determine whether self-reported events of sleep disorders and nighttime urinations may affect the "nondipping" status.From January 2013 to December 2015, we consecutively evaluated 1046 patients with arterial hypertension, performing ABPM, considering a tolerance index calculated on the basis of the patients' responses to a questionnaire.Thirty-eight out of 1046 patients showed complete lack of tolerance to the instrument during the day, whilst 126 during the night. There were no statistically significant differences in daytime and nighttime values of tolerance to the instrument between "dippers" and "nondippers," between "extreme-dippers" and the remaining patients or between "reverse-dippers" and the remaining patients. There were no statistically significant differences in the number of nocturnal awakenings between the groups. However, we found that the number of awakenings followed by urination was higher in "nondipping" patients and in "reverse-dipping" patients compared to the other groups.We found that the poor tolerance to the instrument does not seem to influence the BP "dipping" phenomenon among hypertensive individuals. Moreover, we think that in the evaluation of the ABPM data, factors, such as nocturnal urination and sleep disorders, need to be carefully taken into account, since may lead to a higher incidence of "nondipping" pattern.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Reproducibility of the hyperbaric index as a measure of blood pressure excess.

The approach of establishing a time-specified tolerance limit reflecting the circadian variability in blood pressure and then determining the hyperbaric index, the area of blood pressure excess above the upper limit of the tolerance interval, has been proposed for diagnosing hypertension as well as for evaluating the patient's response to treatment. The retrospective evaluation of this test pro...

متن کامل

Influence of quality of sleep on the nocturnal decline in blood pressure during ambulatory blood pressure monitoring.

OBJECTIVE To assess the influence of the quality of sleep on the nocturnal physiological drop in blood pressure during ambulatory blood pressure monitoring. METHODS We consecutively assessed ambulatory blood pressure monitoring, the degree of tolerance for the examination, and the quality of sleep in 168 patients with hypertension or with the suspected "white-coat" effect. Blood pressure fall...

متن کامل

Effects of Ramadan fasting on ambulatory blood pressure in hypertensive patients

Background: Previous studies have indicated that Ramadan fasting has beneficial effects on cardiovascular risk factors, specially blood pressure and heart rate. In the present study, the effect of Ramadan fasting on 24-hour ambulatory blood pressure and heart rate has been investigated. Materials and Methods: This prospective observational study was conducted on two groups of individuals. Six p...

متن کامل

Resistant hypertension, case based approach to diagnosis and management: case report

Background: Resistant hypertension is defined when the blood pressure remains elevated above the therapeutic target levels despite the use of three antihypertensive agents including calcium channel blocker (CCB), renin-angiotensin system (RAS) blocker and a diuretic. These drugs should be used at maximally tolerated doses and white coat effect and non-adherence should also be excluded. In this ...

متن کامل

Noninvasive 24 hour ambulatory blood pressure monitoring: current status.

Noninvasive intermittent blood pressure monitoring was first developed 30 years ago.' It is now evolving from its former role as a somewhat esoteric research tool to becoming a clinically useful procedure for the evaluation ofhypertensive patients. In this review we outline its historical development, compare noninvasive 24-hour ambulatory blood pressure monitoring with the other available meth...

متن کامل

Measurement of blood pressure in the office.

Measurement of Blood Pressure in the Office To the Editor: The algorithm for office blood pressure recently proposed by Myers et al1 does not allow for the discernment of isolated clinic or masked hypertension. In a recent study we measured observed automated blood pressure (nurse present), unobserved automated blood pressure (3 readings at 3-minute intervals after 5 minutes of rest), and ambul...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 96  شماره 

صفحات  -

تاریخ انتشار 2017