Detection of cortical thickness correlates of cognitive performance: Reliability across MRI scan sessions, scanners, and field strengths
نویسندگان
چکیده
In normal humans, relationships between cognitive test performance and cortical structure have received little study, in part, because of the paucity of tools for measuring cortical structure. Computational morphometric methods have recently been developed that enable the measurement of cortical thickness from MRI data, but little data exist on their reliability. We undertook this study to evaluate the reliability of an automated cortical thickness measurement method to detect correlates of interest between thickness and cognitive task performance. Fifteen healthy older participants were scanned four times at 2-week intervals on three different scanner platforms. The four MRI data sets were initially treated independently to investigate the reliability of the spatial localization of findings from exploratory whole-cortex analyses of cortical thickness-cognitive performance correlates. Next, the first data set was used to define cortical ROIs based on the exploratory results that were then applied to the remaining three data sets to determine whether the relationships between cognitive performance and regional cortical thickness were comparable across different scanner platforms and field strengths. Verbal memory performance was associated with medial temporal cortical thickness, while visuomotor speed/set shifting was associated with lateral parietal cortical thickness. These effects were highly reliable - in terms of both spatial localization and magnitude of absolute cortical thickness measurements - across the four scan sessions. Brain-behavior relationships between regional cortical thickness and cognitive task performance can be reliably identified using an automated data analysis system, suggesting that these measures may be useful as imaging biomarkers of disease or performance ability in multicenter studies in which MRI data are pooled.
منابع مشابه
Harmonization of cortical thickness measurements across scanners and sites
With the proliferation of multi-site neuroimaging studies, there is a greater need for handling non-biological variance introduced by differences in MRI scanners and acquisition protocols. Such unwanted sources of variation, which we refer to as "scanner effects", can hinder the detection of imaging features associated with clinical covariates of interest and cause spurious findings. In this pa...
متن کاملMRI-derived measurements of human subcortical, ventricular and intracranial brain volumes: Reliability effects of scan sessions, acquisition sequences, data analyses, scanner upgrade, scanner vendors and field strengths
Automated MRI-derived measurements of in-vivo human brain volumes provide novel insights into normal and abnormal neuroanatomy, but little is known about measurement reliability. Here we assess the impact of image acquisition variables (scan session, MRI sequence, scanner upgrade, vendor and field strengths), FreeSurfer segmentation pre-processing variables (image averaging, B1 field inhomogene...
متن کاملReproducibility of Brain Morphometry from Short-Term Repeat Clinical MRI Examinations: A Retrospective Study.
PURPOSE To assess the inter session reproducibility of automatic segmented MRI-derived measures by FreeSurfer in a group of subjects with normal-appearing MR images. MATERIALS AND METHODS After retrospectively reviewing a brain MRI database from our institute consisting of 14,758 adults, those subjects who had repeat scans and had no history of neurodegenerative disorders were selected for mo...
متن کاملReliability of MRI-derived measurements of human cerebral cortical thickness: the effects of field strength, scanner upgrade and manufacturer.
In vivo MRI-derived measurements of human cerebral cortex thickness are providing novel insights into normal and abnormal neuroanatomy, but little is known about their reliability. We investigated how the reliability of cortical thickness measurements is affected by MRI instrument-related factors, including scanner field strength, manufacturer, upgrade and pulse sequence. Several data processin...
متن کاملAssessing the Changes of Cortical Thickness in Alzheimer Disease With MRI Using Freesurfer Software
Introduction: In this study, we intend to determine the correlation between the thickness of the cerebral cortex and the severity of the cognitive disorder in Alzheimer disease (AD). Methods: A total of 20 (14 women and 6 men) patients diagnosed with AD with a Mean age of 72.95 years, and 10 (7 women and 3 men) cognitively normal (CN) subjects with a Mean age of 70.50 years were included in th...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- NeuroImage
دوره 39 1 شماره
صفحات -
تاریخ انتشار 2008