Clinical image quality perception and its relation to NECR measurements in PET
نویسندگان
چکیده
BACKGROUND The purpose of this study is to describe a clinical relation of noise equivalent count rate (NECR) - an objective measurement of positron emission tomography (PET) systems - measured in a large number of patients, to clinical image quality of PET and their relation to 18F-fluoro-2-deoxyglucose (FDG) activity and patient's weight. METHODS A total of 71 consecutive patients were evaluated in this retrospective study. All data was automatically analysed using Matlab to estimate the noise equivalent count rate. Then, image quality was evaluated according to two subjective scores: the IQ local score was a 3-point scale assigned to each bed position in all patients and the IQ global score was a 10-point scale assigned after evaluating the coronal whole-body PET. Patient data was also analysed concerning weight, body mass index, FDG dose at the start of acquisition (D Acq), presence of bowel uptake and presence of FDG-positive pathologic lesions. Two additional parameters were defined for each patient: the ratio between D Acq and patient weight (R DW) and the ratio between D Acq and patient BMI (R DBMI). RESULTS Clinically perceived image quality in PET has a significant positive correlation with NECR measured in patients, R DW, R DBMI and presence of pathologic lesions. Clinical image quality furthermore has significant negative correlation with weight, body mass index (BMI) and presence of bowel uptake. Thresholds of R DW and R DBMI in which clinical IQ is good to excellent in more than 90% of the patients were 2.6 and 8.0, respectively. CONCLUSIONS Clinically perceived image quality in PET systems is positively and significantly related to NECR measured in patients. An optimal threshold for the R DW and R DBMI was defined in which clinical IQ is good to excellent in more than 90% of patients. With this data, it is possible to extrapolate technical as well as clinical image quality to other PET system and to predict clinical image perception.
منابع مشابه
Dose Optimization in TOF-PET/MR Compared to TOF-PET/CT
PURPOSE To evaluate the possible activity reduction in FDG-imaging in a Time-of-Flight (TOF) PET/MR, based on cross-evaluation of patient-based NECR (noise equivalent count rate) measurements in PET/CT, cross referencing with phantom-based NECR curves as well as initial evaluation of TOF-PET/MR with reduced activity. MATERIALS AND METHODS A total of 75 consecutive patients were evaluated in t...
متن کاملF -FDG PET/CT Image Quality
The choice of injected dose of 18 F -FDG and acquisition time is important in obtaining consistently high-quality PET images. The aim of this study was to determine the optimal acquisition protocols based on patient weight for 3-dimensional lutetium oxyorthosilicate PET/CT. Methods: This study was a retrospective analysis of 76 patients ranging from 29 to101 kg who were injected with 228–395.2 ...
متن کاملPatient weight-based acquisition protocols to optimize (18)F-FDG PET/CT image quality.
UNLABELLED The choice of injected dose of (18)F-FDG and acquisition time is important in obtaining consistently high-quality PET images. The aim of this study was to determine the optimal acquisition protocols based on patient weight for 3-dimensional lutetium oxyorthosilicate PET/CT. METHODS This study was a retrospective analysis of 76 patients ranging from 29 to 101 kg who were injected wi...
متن کاملEvaluation of PET Scanner Performance in PET/MR and PET/CT Systems: NEMA Tests
OBJECTIVE The aim of the present study was to compare the performance of positron emission tomography (PET) component of PET/computed tomography (CT) with new emerging PET/magnetic resonance (MR) of the same vendor. METHODS According to National Electrical Manufacturers Association NU2-07, five separate experimental tests were performed to evaluate the performance of PET scanner of General El...
متن کاملDosage optimization in positron emission tomography: state-of-the-art methods and future prospects.
Positron emission tomography (PET) is widely used nowadays for tumor staging and therapy response in the clinic. However, average PET radiation exposure has increased due to higher PET utilization. This study aims to review state-of-the-art PET tracer dosage optimization methods after accounting for the effects of human body attenuation and scan protocol parameters on the counting rate. In part...