Method for manipulating peak flow measurements producing falsely raised readings.

نویسندگان

  • S Ross
  • D P Cochran
چکیده

Methods by which patients can artificially produce raised peak flow measurements have been described. We recently observed a patient manipulating the peak flow meter in a way that had not been described before. A study was therefore undertaken to determine if this technique could repeatedly produce clinically significant changes in peak flow readings. Fifteen adults, using a mini-Wright peak flow meter, made five measurements using the correct technique followed by five manipulated measurements under observation. Significant increases in peak flow measurements were observed in 14 of the 15 subjects. The mean increase in peak flow rate using the incorrect technique was 56% (range -4% to 86%). Clinicians should be aware that patients might employ this technique to manipulate measurements which could have consequences for management.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Peak Expiratory Flow Rate in Healthy Children from Tehran

Background: Measuring peak expiratory flow rate has been suggested as an important tool in asthma management by all international guidelines.  Objective: Studies on various populations have shown considerable variations in normal values of peak expiratory flow rate. Since reference standards for Iranian children are not available, the present study was performed to establish these standards. Me...

متن کامل

Accuracy and reproducibility of the Assess peak flow meter.

The variability of peak flow measurements was studied in 24 patients with airway obstruction, using 12 Assess peak flow meters and a Fleisch pneumotachograph type 4 as a standard. The Assess peak flow meter gave systematic under-readings of 19-34% (low accuracy). The value scale of the Assess peak flow meter should be adjusted. As systematic under-readings do not influence the variability in pe...

متن کامل

A Comparative Study of Blood Glucose Measurements Using Glucometer Readings and the Standard Method in the Diagnosis of Neonatal Hypoglycemia

Background: Hypoglycemia is one of the most common neonatal disorders, associated with severe complications. There has been a great deal of controversy regarding the definition and screening of hypoglycemia. Therefore, in this study, we aimed to determine a cut-off value for blood glucose level in glucometer readings. Methods: This cross-sectional study was conducted on 238 newborns at risk of ...

متن کامل

Mastitis in the male--a rare complication of mumps.

peak flow readings begins and hence this measurement is of less diagnostic value. Technically it is quite easy to alter the whistle so that more accurate readings are obtained above 300 1./min., but when this is done the performance of the whistle is less discriminating for small variations at low flow rates. Overestimation of the peak expiratory flow rate by the whistle is negligible (2%). The...

متن کامل

The effect of patient technique and training on the accuracy of self-recorded peak expiratory flow.

The aim of the study was to investigate the difference between encouraged self-recorded peak expiratory flow (PEF) with unobserved readings and to investigate any long-term changes in PEF self-recording. Patients were trained in the PEF technique and asked to keep 2-hourly PEF records until the next clinic visit. The patients PEF were then rechecked at the second clinic visit by a series of two...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Thorax

دوره 56 6  شماره 

صفحات  -

تاریخ انتشار 2001