Motion Characteristics of the VIRTTEX Motion System
نویسنده
چکیده
The motion characteristics of the VIRTTEX motion system were measured using a set of tests similar to those suggested in AGARD Report AR-144. The measurements were devised to measure the performance of existing motion systems, aid in the procurement of new motion systems, and help identify root causes of poor performance. Transfer functions (both within degree-of-freedom and between degree-of-freedom), 1⁄2 Hz noise levels, signal to noise contours, dynamic threshold measurements and hystersis measurements were all conducted. Before these tests, the VIRTTEX motion system was tuned with an emphasis on high bandwidth. The motion system as tuned, has a bandwidth greater than 13Hz on all degrees-of-freedom. The dynamics threshold is 15ms and the motion system has no significant hystersis. The transfer function measurements revealed larger than expected levels of cross talk between degrees-of-freedom. The motion system also exhibits turn-around bump and non-linearity at large velocities and accelerations. Further experience with the complex MTS controller is expected to lead to improvements in both cross talk and non-linearity. This measurement process will be repeated once planned improvements to the system are complete.
منابع مشابه
Experimental Evaluation of IRWEC1, a Novel Offshore Wave Energy Converter
This paper describes the innovative offshore point-absorber wave energy converter (WEC), IRWEC1, under development by the Hydrodynamics, Acoustics and Marine propulsion Group at Babol Noshirvani University of Technology. Totally enclosed in an outer shell, with no external moving parts, IRWEC1 is completely sealed which make it a robust and trustable system. Important motion for this WEC is the...
متن کاملارتباط میان دامنه حرکتی و انحنای لوردوتیک ستون فقرات در ناحیه کمری با کمردردهای غیراختصاصی
Aims and Background: Non-specific low back pain has direct impact on quality of life, active days at work and healthcare cost. The purpose of this investigation was to study the relationship between lumbar lordosis and lumbar range of motion with non-specific low back pain. Methods and Materials: 50 students of kharazmi University (mean age :24 years, mean weight: 75.72 kg, mean height :180.5 c...
متن کاملAnalysis of Motion of Micro-Gripper Exposed to the Electric Field and Thermal Stresses for Using in Micro-Robotics
Micro system technology is a relatively new scientific research that deals with the development and study of properties of materials in micro dimensions. Micro-grippers are widely used in switching, positioning, and assembling micron sized components in micro-robotics. In this study, the static and dynamic behavior of visco-elastic Micro-Tweezers under the thermal and electrostatic field is...
متن کاملP-34: Effect of Glucose on Buffalo Epididymal Sperm Motion Characteristics, Viability and Cytoplsmic droplets During 24 Hours Incubation
Background: The recovery of sperm from the cauda epididymis may be the last chance to conserve, genetic Materials of valuable farm animals. Sperm utilize glucose as source of energy through glycolysis and oxidative phosphorylation to provide motility and movement. While endogenous glucose of the culture media has little potential to preserve sperm motility and viability for long period of time ...
متن کاملDerivation of Equation of Motion for the Pillow-Shape Seismic Base Isolation System
Rolling-based seismic isolation systems, in which rollers of circular or non-circular section are used, are less expensive and easier to manufacture. However, this type of isolation suffers from either lack of restoring or re-centering capability, or weakness against uplift forces. To resolve the first shortcoming the use of elliptical as well as pillow-shape rolling parts has been suggested, a...
متن کامل