99% Efficiency True-Bridgeless Totem-Pole PFC Based on GaN HEMTs

نویسندگان

  • Liang Zhou
  • YiFeng Wu
چکیده

Liang Zhou, member IEEE and YiFeng Wu, member IEEE Transphorm, Inc. 75 Castilian Dr., Goleta, CA, 93117 USA [email protected] Abstract: This paper presents a true bridgeless totem-pole Power-Factor-Correction (PFC) circuit using GaN HEMT. Enabled by a diode-free GaN power HEMT bridge with low reverse-recovery charge, very-high-efficiency single-phase AC-DC conversion is realized using a totem-pole topology without the limit of forward voltage drop from a fast diode. When implemented with a pair of sync-rec MOSFETs for line rectification, 99% efficiency is achieved at 230V ac input and 400 dc output in continuous-current mode.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Totem-Pole Power-Factor-Correction Converter under Critical-Conduction-Mode Interleaved Operation

This paper proposes a new power-factor-correction (PFC) topology, and explains its operation principle, its control mechanism, related application problems followed by experimental results. In this proposed topology, critical-conduction-mode (CRM) interleaved technique is applied to a bridgeless PFC in order to achieve high efficiency by combining benefits of each topology. This application is ...

متن کامل

An Interleaved Totem-Pole Power Factor Correction Converter

This paper explains about basic working principles, implementation problems, and experimental results of a new power factor correction (PFC) topology. In this proposed topology, a totem-pole boost PFC circuit that works under interleaved critical-conduction-mode (CRM) condition is presented. The circuit is developed towards high efficiency, high performance, lowcost, simple control scheme, and ...

متن کامل

Simulation of Closed Loop Controlled Bridgeless Pfc Boost Converter

Conventional boost PFC converter suffers from the high conduction loss in the input rectifier-bridge. Higher efficiency can be achieved by using the bridgeless boost topology. In this paper, digital simulation of bridgeless PFC boost rectifiers, also called dual boost PFC rectifiers, is presented. Performance comparison between the conventional PFC boost rectifier and the bridgeless PFC boost r...

متن کامل

UCC28070 Implement Bridgeless Power Factor Correction (PFC) Pre-Regulator Design

ABSTRACT Bridgeless power factor correction (PFC) topology is attracting attention as a means of satisfying the new high-efficiency requirements. This application report reviews the UCC28070 and its design considerations for bridgeless PFC. It present a bridgeless solution that is relatively easy to implement in that it does not require any additional circuitry for current sensing and that the ...

متن کامل

Classification and Comparison of BPFC Techniques: A Review

Power factor correction (PFC) techniques play an important role in green power and energy-saving technology. Based on conventional boost PFC, many novel topologies and control strategies of bridgeless PFC(BPFC) have been proposed, and BPFC reduces the number of devices, the losses and improves the power density as well. In this paper, it discusses and investigates a variety of low conduction lo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013