A closed-loop compressive-sensing-based neural recording system.
نویسندگان
چکیده
OBJECTIVE This paper describes a low power closed-loop compressive sensing (CS) based neural recording system. This system provides an efficient method to reduce data transmission bandwidth for implantable neural recording devices. By doing so, this technique reduces a majority of system power consumption which is dissipated at data readout interface. The design of the system is scalable and is a viable option for large scale integration of electrodes or recording sites onto a single device. APPROACH The entire system consists of an application-specific integrated circuit (ASIC) with 4 recording readout channels with CS circuits, a real time off-chip CS recovery block and a recovery quality evaluation block that provides a closed feedback to adaptively adjust compression rate. Since CS performance is strongly signal dependent, the ASIC has been tested in vivo and with standard public neural databases. MAIN RESULTS Implemented using efficient digital circuit, this system is able to achieve >10 times data compression on the entire neural spike band (500-6KHz) while consuming only 0.83uW (0.53 V voltage supply) additional digital power per electrode. When only the spikes are desired, the system is able to further compress the detected spikes by around 16 times. Unlike other similar systems, the characteristic spikes and inter-spike data can both be recovered which guarantes a >95% spike classification success rate. The compression circuit occupied 0.11mm(2)/electrode in a 180nm CMOS process. The complete signal processing circuit consumes <16uW/electrode. SIGNIFICANCE Power and area efficiency demonstrated by the system make it an ideal candidate for integration into large recording arrays containing thousands of electrode. Closed-loop recording and reconstruction performance evaluation further improves the robustness of the compression method, thus making the system more practical for long term recording.
منابع مشابه
Design of robust controller by neuro-fuzzy system in a prescribed region via state feedback
In this paper, first a new algorithm for pole assignment of closed-loop multi-variable controllable systems in a prescribed region of the z-plane is presented. Then, robust state feedback controllers are designed by implementing a neural fuzzy system for the placement of closed-loop poles of a controllable system in a prescribed region in the left-hand side of z-plane. A new method based on the...
متن کاملNeuro-PD Controller of Structural System to Mitigate Earthquake Vibrations
In this paper, stabilization of the structural system against earthquake is presented. Because the conventional PD controller is popular and simple in design, our controller is based on PD controller. The main problem of such a controller is its inability to produce desired response and instability against variations in the properties of the structural system. To obviate this issue, the neu...
متن کاملT ALK # 1 Title : Interfacing Brain and Machines : Challenges and Perspectives
Interfacing brain and machines involve recording neural signals, extracting information from them and applying stimulations in closed loop. Applications are huge: from therapies for epilepsy and other kind of brain seizures to the control of prosthesis. Challenges are enormeous and truly multi-disciplinary: including, design of ultra low-noise microelectronic circuits with minimum power budget,...
متن کاملNeural Recording System with 8 Channel Neural Amplifier and Logarithmic ADC
This work proposes a low-power 8 channel neural recording system for use in advanced closed-loop neurostimulation applications for the detection and treatment of neurological disorders such as Parkinson’s disease. The analog front end senses and filters the neural activity with eight low-noise preamplifiers and band-pass filters. The neural sensing signals are multiplexed to a single logarithmi...
متن کاملControl of Flexible Link Robot using a Closed Loop Input-Shaping Approach
This paper is has addressed the Single Flexible Link Robot. The dynamical model is derived using Euler-Lagrange equation and then a proper controller is designed to suppress a vibration based-on Input-Shaping (IS) method. But, IS control method is an open loop strategy. Due to the weakness of open loop control systems, a closed loop IS control system is proposed. The achieved closed loop c...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of neural engineering
دوره 12 3 شماره
صفحات -
تاریخ انتشار 2015