Microresonator mass sensors for detection of Bacillus anthracis Sterne spores in air and water.

نویسندگان

  • Angelica P Davila
  • Jaesung Jang
  • Amit K Gupta
  • Tom Walter
  • Arthur Aronson
  • Rashid Bashir
چکیده

Towards the goal of developing a real-time monitoring device for microorganisms, we demonstrate the use of microcantilevers as resonant mass sensors for detection of Bacillus anthracis Sterne spores in air and liquid. The detection scheme was based on measuring resonant frequency decrease driven by thermally induced oscillations, as a result of the added mass of the spores with the use of a laser Doppler vibrometer (LDV). Viscous effects were investigated by comparing measurements in air and deionized (DI) water along with theoretical values. Moreover, biological experiments were performed which involved suspending spores onto the cantilevers and performing mass detection in air and water. For detection of spores in water, the cantilevers were functionalized with antibodies in order to fix the spores onto the surface. We demonstrate that as few as 50 spores on the cantilever can be detected in water using the thermal noise as excitation source. Measurement sensitivity of 9.23 Hz/fg for air and 0.1 Hz/fg for water were obtained. These measurements were compared with theoretical values and sources of improvement in cantilever sensitivity in a viscous medium were also discussed. It is expected that by driving the cantilevers and using higher order modes, detection of a single spore in liquids should be achievable.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Stability and potency studies of anthrax vaccine (Bacillus anthracis 34F2 Sterne strain) in Iran

  For evaluation the stability and potency of anthrax vaccine prepared in Razi Vaccine and Serum Research Institute in Iran, samples of different batches of vaccine were kept at 4-8 °C (refrigerator), 20-25 °C (room temperature) and 37 °C (incubator).The viable spores/ml of vaccines were determined using plate–counting method before and after holding at different temperatures monthly. Vaccine p...

متن کامل

Inactivation of spores of Bacillus anthracis Sterne, Bacillus cereus, and Bacillus thuringiensis subsp. israelensis by chlorination.

Three species of Bacillus were evaluated as potential surrogates for Bacillus anthracis for determining the sporicidal activity of chlorination as commonly used in drinking water treatment. Spores of Bacillus thuringiensis subsp. israelensis were found to be an appropriate surrogate for spores of B. anthracis for use in chlorine inactivation studies.

متن کامل

Selectivity of Piezoelectric-excited Millimeter-sized Cantilever (pemc) Sensors to Bacillus Anthracis Spores in the Presence of Bacillus Thuringiensis and Bacillus Cereus Spores in a Flow Cell

We report a highly sensitive, rapid and reliable method for the detection of Bacillus Anthracis spores at 300/mL using a piezoelectric-excited millimeter-sized cantilever (PEMC) sensor. Antibody specific to Bacillus anthracis (BA, Sterne strain 7702) spores was immobilized on PEMC sensors, and exposed to spores (300 to 3x10 spores/mL). The resonant frequency decreased at a rate proportional to ...

متن کامل

UV resistance of Bacillus anthracis spores revisited: validation of Bacillus subtilis spores as UV surrogates for spores of B. anthracis Sterne.

Recent bioterrorism concerns have prompted renewed efforts towards understanding the biology of bacterial spore resistance to radiation with a special emphasis on the spores of Bacillus anthracis. A review of the literature revealed that B. anthracis Sterne spores may be three to four times more resistant to 254-nm-wavelength UV than are spores of commonly used indicator strains of Bacillus sub...

متن کامل

Detection and fate of Bacillus anthracis (Sterne) vegetative cells and spores added to bulk tank milk.

A preparation of Bacillus anthracis (Sterne strain) spores was used to evaluate commercially available reagents and portable equipment for detecting anthrax contamination by using real-time PCR and was used to assess the fate of spores added directly to bulk tank milk. The Ruggedized Advanced Pathogen Identification Device (RAPID) was employed to detect spores in raw milk down to a concentratio...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Biosensors & bioelectronics

دوره 22 12  شماره 

صفحات  -

تاریخ انتشار 2007