Pulmonary vein isolation: comparison of bipolar and unipolar electrograms at successful and unsuccessful ostial ablation sites.

نویسندگان

  • Hiroshi Tada
  • Hakan Oral
  • Kristina Wasmer
  • Radmira Greenstein
  • Frank Pelosi
  • Bradley P Knight
  • S Adam Strickberger
  • Fred Morady
چکیده

INTRODUCTION No prior studies have quantitatively analyzed the characteristics of bipolar or unipolar electrograms that may be helpful in identifying successful ostial ablation sites in patients with atrial fibrillation undergoing segmental pulmonary vein isolation. METHODS AND RESULTS The characteristics of bipolar and unipolar electrograms recorded at 185 successful and 120 unsuccessful ostial pulmonary venous ablation sites were analyzed in 21 patients with atrial fibrillation. A decapolar Lasso catheter was positioned near the ostia of the pulmonary veins, and a conventional ablation catheter was used to deliver radiofrequency energy at individual ostial sites where pulmonary vein potentials were recorded. With both bipolar and unipolar recordings, the only timing parameter that distinguished successful from unsuccessful ostial ablation sites was the timing of the electrogram recorded by the ablation catheter relative to the earliest pulmonary vein potential recorded by the Lasso catheter. With both bipolar and unipolar recordings, electrograms demonstrated a larger amplitude at successful than at unsuccessful ablation sites. Unipolar electrograms had a steeper intrinsic deflection at successful than at unsuccessful ostial ablation sites. The morphologies of the unipolar electrograms recorded by the ablation catheter and by the contiguous electrode of the Lasso catheter usually were identical. CONCLUSION In patients undergoing segmental isolation of the pulmonary veins, unipolar recordings provide more information than bipolar recordings helpful in distinguishing successful from unsuccessful ostial ablation sites. Furthermore, unipolar recordings, but not bipolar recordings, allow accurate localization of the position of the ablation catheter relative to the electrodes of the Lasso catheter.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Conducting randomized trials in the electrophysiology laboratory: lessons from a randomized comparison of recording methods during pulmonary vein isolation by segmental ostial ablation.

Accurate identification of pulmonary vein (PV) potentials during segmental ostial ablation for PV isolation is very important to completely isolate the PVs and also to avoid unnecessary applications of radiofrequency energy. A prior post hoc analysis of unipolar and bipolar electrograms recorded from successful and unsuccessful ablation sites demonstrated that unipolar electrograms recorded at ...

متن کامل

Randomized comparison of bipolar versus unipolar plus bipolar recordings during segmental ostial ablation of pulmonary veins.

INTRODUCTION Segmental ostial ablation to isolate pulmonary veins is guided by pulmonary vein potentials. The aim of this prospective randomized study was to compare the utility of unipolar plus bipolar electrograms versus only bipolar electrograms as a guide for segmental ablation to isolate the pulmonary veins in patients with atrial fibrillation. METHODS AND RESULTS Isolation of the left s...

متن کامل

Usefulness of filtered unipolar electrogram morphology for evaluating transmurality of ablated lesions during pulmonary vein isolation

BACKGROUND Although alteration of the amplitude and morphology of bipolar electrograms is used widely as a guide of the ablation effect, there is little information concerning unipolar electrograms. The amplitude and morphology of filtered bipolar (BP) and filtered unipolar (UP) electrograms were compared during pulmonary vein isolation in patients with atrial fibrillation. METHODS BP (30-250...

متن کامل

Comparison of endocardial activation times at effective and ineffective ablation sites within the pulmonary veins.

INTRODUCTION Recent studies demonstrated that atrial arrhythmias may be generated within pulmonary veins. The purpose of this study was to compare the endocardial activation times at effective and ineffective ablation sites during radiofrequency catheter ablation of arrhythmias initiated or generated within pulmonary veins. METHODS AND RESULTS Twenty-one of 28 patients without structural hear...

متن کامل

Role of the coronary sinus in maintenance of atrial fibrillation.

INTRODUCTION Bursts of tachycardia arising in the pulmonary veins may play an important role in perpetuating atrial fibrillation (AF). However, the role of the coronary sinus (CS) in the perpetuation of AF has been unclear. The aim of this study was to determine whether the CS plays a role in perpetuation of AF. METHODS AND RESULTS Pulmonary vein isolation was performed by segmental ostial ab...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of cardiovascular electrophysiology

دوره 13 1  شماره 

صفحات  -

تاریخ انتشار 2002