Performance of cat retinal ganglion cells at low light levels

نویسندگان

  • W R Levick
  • L N Thibos
  • T E Cohn
  • D Catanzaro
  • H B Barlow
چکیده

Responses of brisk-sustained cat retinal ganglion cells were examined using receiver operating characteristic (ROC) analysis. Stimuli were brief luminance changes superimposed upon a weak steady pedestal ranging from 27 to 47,000 quanta (507 nm) per second at the cornea. Overall quantum efficiencies of cells ranged up to approximately 13% and were compatible with previous estimates at absolute threshold. The main work was done on on-center cells, but a small sample of off-center units behaved similarly. Experimental ROC curves verified a set of qualitative predictions based on a theoretical treatment of performance, assuming that response variability resulted solely from quantum fluctuations. However, quantitative predictions were not fulfilled. The discrepancy could be resolved by postulating a source of added internal variance, R, the value of which could then be deduced from the experimental measurements. A ganglion cell model limited by a fixed amount of added variance from physiological sources and having access to a fixed fraction of incident quanta can account quantitatively for (a) slopes of ROC curves, (b) variation of detectability with magnitude of both increments and decrements, and (c) performance over a range of pedestal intensities. Estimates of the proportion of incident quanta used ranged up to 29% under some conditions, a figure approximately matching estimates of the fraction of corneal quanta that isomerize rhodopsin in the cat.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Receptive Fields in Cat Striate Cortex

In the central nervous system the visual pathway from retina to striate cortex provides an opportunity to observe and compare single unit responses at several distinct levels. Patterns of light stimuli most effective in influencing units at one level may no longer be the most effective at the next. From differences in responses at successive stages in the pathway one may hope to gain some under...

متن کامل

Local edge detectors: a substrate for fine spatial vision at low temporal frequencies in rabbit retina.

Visual acuity is limited by the size and density of the smallest retinal ganglion cells, which correspond to the midget ganglion cells in primate retina and the beta-ganglion cells in cat retina, both of which have concentric receptive fields that respond at either light-On or light-Off. In contrast, the smallest ganglion cells in the rabbit retina are the local edge detectors (LEDs), which res...

متن کامل

The spectral sensitivity of dark- and light-adapted cat retinal ganglion cells.

The spectral sensitivity of cat retinal ganglion neurons (RGNs) was determined by means of extracellular recordings under scotopic and photopic conditions, in both receptive field center and surround. Test stimuli were presented either as square-wave single flashes or as flicker stimuli. Chromatic adaptation was achieved by a large steady monochromatic background field. In the dark-adapted stat...

متن کامل

Spatiotemporal organization of the receptive fields of retinal ganglion cells in the cat: a phenomenological model.

The reorganization of ganglion cell receptive fields (RFs) with different levels of light adaptation was investigated by means of spontaneous contour planes (SCPs). The SCP shows the spatiotemporal characteristics of the cell responses to a small bar of light switched on and off at 31 separate points along the RF horizontal axis. We assume a radial symmetry of RFs. A mathematical function descr...

متن کامل

Spatiotemporal frequency responses of cat retinal ganglion cells

Spatiotemporal frequency responses were measured at different levels of light adaptation for cat X and Y retinal ganglion cells. Stationary sinusoidal luminance gratings whose contrast was modulated sinusoidally in time or drifting gratings were used as stimuli. Under photopic illumination, when the spatial frequency was held constant at or above its optimum value, an X cell's responsivity was ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 82  شماره 

صفحات  -

تاریخ انتشار 1983