PURPOSE The purpose of this study was to determine whether radiographically demonstrated proximal stent graft contour can be used as a marker for security of proximal neck fixation after endovascular aneurysm repair. METHODS Stent graft structure was examined in 100 consecutive patients with abdominal aortic aneurysms who were treated with the stent graft. Stent graft integrity, stent contour, angulation, compression, and position were assessed by use of plain abdominal radiography, and the results were correlated with contrast computed tomography (CT) scanning, clinical findings, and outcomes. Repeated imaging was carried out during follow-up of 3 to 38 (mean, 12) months. RESULTS Stent graft repair was successful in all 100 patients. No stent fractures were identified. Concentric compression of the proximal portion of the stent graft was visible in 69% of patients and reflected deliberate oversizing of the stent graft at the time of implantation. In 5% of patients, a short eccentric compression deformity of the proximal stent was observed. This finding was associated with an increased risk of stent graft migration (P <.01) and with an increased risk for development of a late proximal (type I) endoleak (P <.01). Compared with CT scanning, abdominal radiography was less useful for assessment of short distances of migration (sensitivity 67%; specificity 79%). However, they provided better definition of the stent graft in relation to bony landmarks and better visualization of aortic calcification than CT with three-dimensional reconstruction. CONCLUSION Plain abdominal radiographs are important in the postoperative evaluation of patients with aortic stent grafts. They allow for more precise evaluation of the structural elements of the stent graft than CT scanning and may disclose inadequate proximal fixation by demonstration of an eccentric compression deformity. They are less useful for assessment of migration.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Management of a large coronary artery aneurysm with graft-coated stent during the acute phase of myocardial infarction

Coronary aneurysms in adults are rare clinical entities. Herein, we presented a 54-year-old man who was admitted with an acute extensive anterior myocardial infarction. The emergency coronary angiography revealed an isolated large aneurysm at the proximal segment of the left anterior descending coronary artery. The patient was successfully treated with a graft-coated stent

متن کامل

The importance of iliac fixation in prevention of stent graft migration.

OBJECTIVE Secure proximal fixation of endografts to the infrarenal aortic neck is known to be important in the short- and long-term success of endovascular aneurysm repair. We sought to determine the relative importance of distal iliac fixation in preventing endograft migration and adverse clinical events after endovascular aneurysm repair. METHODS We reviewed the outcome of 173 patients trea...

متن کامل

Aneurysm rupture after endovascular repair using the AneuRx stent graft.

OBJECTIVE The purpose of this study was to determine the cause and frequency of aneurysm rupture after endovascular aneurysm repair. METHODS We reviewed each patient who sustained aneurysm rupture among all patients enrolled for endovascular aortic aneurysm repair in phases I, II, and III of the US AneuRx Multicenter Clinical Trial from June 1996 through October 1999. RESULTS A total of 106...

متن کامل

Stent graft migration after endovascular aneurysm repair: importance of proximal fixation.

OBJECTIVE We reviewed the incidence of stent-graft migration after endovascular aneurysm repair in a prospective multicenter trial and identified factors that may predispose to such migration. METHODS All patients who received treatment during the course of the multicenter AneuRx clinical trial were reviewed for evidence of stent-graft migration over 5 years, from 1996 to 2001. Post-deploymen...

متن کامل

The effect of injectable biocompatible elastomer (PDMS) on the strength of the proximal fixation of EVAR-grafts An in-vitro study

Purpose: One of the major concerns in the long-term success of EVAR is stent-graft migration, which can cause type I endoleak and even aneurysm rupture. Fixation depends on the mechanical forces between the graft and both the aortic neck and the blood flow. Therefore there are anatomical restrictions for EVAR, such as short and angulated necks. To improve the fixation of EVAR-grafts, elastomer ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of vascular surgery

دوره 33 3  شماره 

صفحات  -

تاریخ انتشار 2001