Fast time-varying linear filters for suppression of baseline drift in electrocardiographic signals

نویسندگان

  • Jiří Kozumplík
  • Ivo Provazník
چکیده

BACKGROUND The paper presents a method of linear time-varying filtering, with extremely low computational costs, for the suppression of baseline drift in electrocardiographic (ECG) signals. An ECG signal is not periodic as the length of its heart cycles vary. In order to optimally suppress baseline drift by the use of a linear filter, we need a high-pass filter with time-varying cut-off frequency controlled by instant heart rate. METHODS Realization of the high-pass (HP) filter is based on a narrow-band low-pass (LP) filter of which output is subtracted from the delayed input. The base of an LP filter is an extremely low computational cost Lynn's filter with rectangular impulse response. The optimal cut-off frequency of an HP filter for baseline wander suppression is identical to an instantaneous heart rate. Instantaneous length of heart cycles (e.g. RR intervals) are interpolated between QRS complexes to smoothly control cut-off frequency of the HP filter that has been used. RESULTS AND CONCLUSIONS We proved that a 0.5 dB decrease in transfer function, at a time-varying cut-off frequency of HP filter controlled by an instant heart rate, is acceptable when related to maximum error due to filtering. Presented in the article are the algorithms that enable the realization of time-variable filters with very low computational costs. We propose fast linear HP filters for the suppression of baseline wander with time-varying cut-off frequencies controlled by instant heart rate. The filters fulfil accepted professional standards and increase the efficiency of the noise suppression.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Non-Linear Approach to ECG Signal Processing using Morphological Filters

Analysis of the Electrocardiogram (ECG) signals is the pre-requisite for the clinical diagnosis of cardiovascular diseases. ECG signal is degraded by artifacts such as baseline drift and noises which appear during the acquisition phase. The effect of impulse and Gaussian noises is randomly distributed whereas baseline drift generally affects the baseline of the ECG signal; these artifacts induc...

متن کامل

A Pole Radius Varying Notch Filter with Transient Suppression for Electrocardiogram

Noise removal techniques play a vital role in the performance of electrocardiographic (ECG) signal processing systems. ECG signals can be corrupted by various kinds of noise such as baseline wander noise, electromyographic interference, and powerline interference. One of the significant challenges in ECG signal processing is the degradation caused by additive 50 or 60 Hz powerline interference....

متن کامل

A Robust Adaptive Observer-Based Time Varying Fault Estimation

This paper presents a new observer design methodology for a time varying actuator fault estimation. A new linear matrix inequality (LMI) design algorithm is developed to tackle the limitations (e.g. equality constraint and robustness problems) of the well known so called fast adaptive fault estimation observer (FAFE). The FAFE is capable of estimating a wide range of time-varying actuator fault...

متن کامل

Potentials of Evolving Linear Models in Tracking Control Design for Nonlinear Variable Structure Systems

Evolving models have found applications in many real world systems. In this paper, potentials of the Evolving Linear Models (ELMs) in tracking control design for nonlinear variable structure systems are introduced. At first, an ELM is introduced as a dynamic single input, single output (SISO) linear model whose parameters as well as dynamic orders of input and output signals can change through ...

متن کامل

Removal of Low Frequency Noise from ECG signal using Genetic Algorithm

The Electrocardiogram is commonly used technique for non-invasive analysis of the electrical activity of the heart in real-time. Electrocardiographic signals can be degraded by different types of noises like power-line interference, electrode contact, motion artifacts, muscle contraction, baseline drift, instrumental noise and electrosurgical noise. Baseline noise is low frequency signal caused...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 16  شماره 

صفحات  -

تاریخ انتشار 2017