QUIPSS II with window-sliding saturation sequence (Q2WISE).

نویسندگان

  • Ruitian Song
  • Ralf B Loeffler
  • Claudia M Hillenbrand
چکیده

A series of periodic saturation pulses used to minimize the error caused by varying transit delays in assessing perfusion using quantitative imaging of perfusion using a single subtraction II with thin-slice TI(1) periodic saturation (Q2TIPS) increases the specific absorption rate. Quantitative imaging of perfusion using a single subtraction II with window-sliding saturation sequence (Q2WISE) has been developed, in which numerous thin saturation pulses are replaced by two thin pulses and one thick saturation pulse arranged in a window-sliding manner within the labeling region to maintain a sharp slice profile while reducing specific absorption rate. Q2WISE essentially is a hybrid between Q2TIPS and quantitative imaging of perfusion using a single subtraction II for use in specific absorption rate intensive applications. Q2WISE was implemented on a 3 T MRI scanner to measure perfusion rates in the brain and kidneys of eight healthy volunteers and results were compared with those from Q2TIPS. Mean perfusion values of both methods for the brain (75 ± 17 [Q2WISE] and 74 ± 13 mL/100 g/min [Q2TIPS]) and kidney (308 ± 48 [Q2WISE] and 299 ± 43 mL/100 g/min [Q2TIPS]) were in very good agreement.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

QUIPSS II with thin-slice TI1 periodic saturation: a method for improving accuracy of quantitative perfusion imaging using pulsed arterial spin labeling.

Quantitative imaging of perfusion using a single subtraction, second version (QUIPSS II) is a pulsed arterial spin labeling (ASL) technique for improving the quantitation of perfusion imaging by minimizing two major systematic errors: the variable transit delay from the distal edge of the tagged region to the imaging slices, and the contamination by intravascular signal from tagged blood that f...

متن کامل

Quantitative Imaging of Perhsion Using a Single Subtraction (QUIPSS and QUIPSS

In the pulsed arterial spin labeling (ASL) techniques EPISTAR, PICORE, and FAIR, subtraction of two images in which inflowing blood is first tagged and then not tagged yields a qualitative map of perfusion. An important reason this map is not quantitative is that there is a spatially varying delay in the transit of blood from the tagging region to the imaging slice that cannot be measured from ...

متن کامل

QUIPSS II multi-slice perfusion imaging with improved saturation profile

G. S. Pell, D. P. Lewis, R. J. Ordidge, C. A. Branch Brain Research Institute, Heidelberg, VIC, Australia, Nathan Kline Institute, Orangeburg, NY, United States, University College London, London, Middlesex, United Kingdom Synopsis: A novel implementation of the QUIPSS II method for quantitative multi-slice perfusion imaging is demonstrated with an optimized saturation scheme based on a double ...

متن کامل

FDiBC: A Novel Fraud Detection Method in Bank Club based on Sliding Time and Scores Window

One of the recent strategies for increasing the customer’s loyalty in banking industry is the use of customers’ club system. In this system, customers receive scores on the basis of financial and club activities they are performing, and due to the achieved points, they get credits from the bank. In addition, by the advent of new technologies, fraud is growing in banking domain as well. Therefor...

متن کامل

Mining frequent itemsets over data streams using efficient window sliding techniques

Online mining of frequent itemsets over a stream sliding window is one of the most important problems in stream data mining with broad applications. It is also a difficult issue since the streaming data possess some challenging characteristics, such as unknown or unbound size, possibly a very fast arrival rate, inability to backtrack over previously arrived transactions, and a lack of system co...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Magnetic resonance in medicine

دوره 67 4  شماره 

صفحات  -

تاریخ انتشار 2012