Characteristics of Friedel pairs and diffraction contrast tomography with non-perpendicular rotation axis.
نویسندگان
چکیده
The characteristics of Friedel pairs in diffraction contrast tomography (DCT) are studied in the condition that the rotation axis of the sample is not exactly perpendicular to the incident X-ray direction. For the rotation axis approximately aligned along the vertical direction, the Friedel pairs close to the horizontal plane are insensitive to the non-perpendicularity of the rotation axis, and can be used to refine the sample-to-detector distance and X-ray energy, while the Friedel pairs close to the vertical direction are sensitive to the non-perpendicularity of the rotation axis, and can be used to determine the rotation axis orientation. The correct matching proportion of Friedel pairs decreases with increasing non-perpendicularity of the rotation axis. A method of data processing considering rotation axis misalignment is proposed, which significantly increases the correct matching and indexing proportions of the diffraction spots. A pure aluminium polycrystalline sample is investigated using DCT at beamline 4W1A of Beijing Synchrotron Radiation Facility. Based on the analysis of Friedel pairs, the sample-to-detector distance and X-ray energy are refined to be 8.67 mm and 20.04 keV, respectively. The non-perpendicular angle of the rotation axis is calculated to be 0.10°. With these refined geometric parameters, the matching proportion of the spatial position of diffraction spots is 90.62%. Three-dimensional reconstruction of the sample with 13 grains is realised using the algebraic reconstruction technique. It is demonstrated that the precise correction of the orientation of the sample rotation axis is effective in DCT suffering from rotation axis misalignment, and the higher accuracy in determining the rotation axis is expected to improve the reconstruction precision of grains.
منابع مشابه
Three-dimensional grain mapping by x-ray diffraction contrast tomography and the use of Friedel pairs in diffraction data analysis.
X-ray diffraction contrast tomography (DCT) is a technique for mapping grain shape and orientation in plastically undeformed polycrystals. In this paper, we describe a modified DCT data acquisition strategy which permits the incorporation of an innovative Friedel pair method for analyzing diffraction data. Diffraction spots are acquired during a 360 degrees rotation of the sample and are analyz...
متن کاملIdentification of inversion domains in KTiOPO4 via resonant X-ray diffraction
A novel method is presented for the identification of the absolute crystallographic structure in multi-domain polar materials such as ferroelectric KTiOPO4. Resonant (or 'anomalous') X-ray diffraction spectra collected across the absorption K edge of Ti (4.966 keV) on a single Bragg reflection demonstrate a huge intensity ratio above and below the edge, providing a polar domain contrast of ∼270...
متن کاملComputed Tomographic Anatomy of the Thoracic Cavity Vessels in the Rayini Goat
Objectives- To provide a reference anatomy of the thoracic cavity vessels of the Rayini goat by using Computed tomography. Design- Experimented study. Animals- Five healthy Rayini goat. Procedures- Spiral CT images (with and without contrast media) were acquired from the thoracic region perpendicular to long axis of the body. CT windows were adjusted as necessary to have optimized images of ...
متن کاملComputed tomography with linear shift-invariant optical systems.
Optical systems capable of three-dimensional transmission imaging are considered; these systems employ a conventional tomographic setup with an added linear shift-invariant optical system between the sample and the detector. A theoretical analysis is presented of image formation and sample reconstruction in such systems, examples of which include diffraction tomography and phase-contrast tomogr...
متن کاملValue of acoustic rhinometry for measuring nasal valve area.
OBJECTIVE To assess the validity of acoustic rhinometry for measuring nasal valve area in human subjects. STUDY DESIGN A comprehensive study that compared acoustic rhinometry data with computed tomography findings from scans obtained perpendicular to the acoustic axis and perpendicular to the floor of the nose. METHODS Fifty nasal passages of 25 healthy adults with no nasal disease were exa...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of synchrotron radiation
دوره 22 4 شماره
صفحات -
تاریخ انتشار 2015