Potential risk for bacterial contamination in conventional reused ventilator systems and disposable closed ventilator-suction systems

نویسندگان

  • Ya-Chi Li
  • Hui-Ling Lin
  • Fang-Chun Liao
  • Sing-Siang Wang
  • Hsiu-Chu Chang
  • Hung-Fu Hsu
  • Sue-Hsien Chen
  • Gwo-Hwa Wan
چکیده

BACKGROUND Few studies have investigated the difference in bacterial contamination between conventional reused ventilator systems and disposable closed ventilator-suction systems. The aim of this study was to investigate the bacterial contamination rates of the reused and disposable ventilator systems, and the association between system disconnection and bacterial contamination of ventilator systems. METHODS The enrolled intubated and mechanically ventilated patients used a conventional reused ventilator system and a disposable closed ventilator-suction system, respectively, for a week; specimens were then collected from the ventilator circuit systems to evaluate human and environmental bacterial contamination. The sputum specimens from patients were also analyzed in this study. RESULTS The detection rate of bacteria in the conventional reused ventilator system was substantially higher than that in the disposable ventilator system. The inspiratory and expiratory limbs of the disposable closed ventilator-suction system had higher bacterial concentrations than the conventional reused ventilator system. The bacterial concentration in the heated humidifier of the reused ventilator system was significantly higher than that in the disposable ventilator system. Positive associations existed among the bacterial concentrations at different locations in the reused and disposable ventilator systems, respectively. The predominant bacteria identified in the reused and disposable ventilator systems included Acinetobacter spp., Bacillus cereus, Elizabethkingia spp., Pseudomonas spp., and Stenotrophomonas (Xan) maltophilia. CONCLUSIONS Both the reused and disposable ventilator systems had high bacterial contamination rates after one week of use. Disconnection of the ventilator systems should be avoided during system operation to decrease the risks of environmental pollution and human exposure, especially for the disposable ventilator system. TRIAL REGISTRATION ClinicalTrials.gov PRS / NCT03359148.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Closed tracheal suction systems versus open tracheal suction systems for mechanically ventilated adult patients.

BACKGROUND Ventilator-associated pneumonia is a common complication in ventilated patients. Endotracheal suctioning is a procedure that may constitute a risk factor for ventilator-associated pneumonia. It can be performed with an open system or with a closed system. In view of suggested advantages being reported for the closed system, a systematic review comparing both techniques was warranted....

متن کامل

Effectiveness of bacterial disinfectants on surfaces of mechanical ventilator systems.

BACKGROUND Pathogens in healthcare settings can be transmitted via skin contact and environmental media. This study investigates bacterial contamination rate on surfaces of mechanical ventilator systems and bedside equipment. An experimental study evaluates the effectiveness of 75% alcohol in killing bacteria on surfaces. METHODS Surface swab sampling was conducted on ventilator systems and ...

متن کامل

Comparison between open and closed suction systems: a systematic review.

OBJECTIVES This study attempted to identify which is the more effective suction system. The objective was to compare open versus closed suction systems according to a systematic review. METHODS A search of scientific literature was conducted in MedLine, LILACS and Cochrane between 1997 and August 2007 using the key words: endotracheal suction and closed suction. Included were articles that co...

متن کامل

Outcome measures for manual lung hyperinflation: not there yet!

e recent systematic review by Paulus and colleagues provides an insight into manual lung hyperinfl ation (MHI) [1], but deserves further comment. MHI research has generally focused on surrogate measures of secretion clearance, such as lung/thorax compliance [2]. Investigation into the eff ects of MHI on airway secretion clearance is warranted to elucidate the mechanistic and hence potential the...

متن کامل

The impact of closed endotracheal suctioning systems on mechanical ventilator performance.

BACKGROUND Closed endotracheal suctioning during mechanical ventilation is increasingly used, but its impact on ventilator function has not been fully studied. METHODS We evaluated the impact of closed suctioning with 11 critical-care ventilators, during assisted ventilation in pressure-support mode, pressure-assist/control mode, volume-assist/control mode, and during continuous positive airw...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 13  شماره 

صفحات  -

تاریخ انتشار 2018