AIMS To assess the agreement of left ventricular ejection fraction (LVEF) determinations from unenhanced echocardiography, contrast-enhanced echocardiography, magnetic resonance imaging (MRI), and cineventriculography as well as the inter-observer agreement for each method. METHODS AND RESULTS In 120 patients, with evenly distributed EF-groups (> 55, 35-55, < 35%), cineventriculography, unenhanced echocardiography with second harmonic imaging, and contrast echocardiography at low mechanical index with iv administration of SonoVue were performed. In addition, cardiac MRI at 1.5 T using a steady-state free precession sequence was performed in a subset of 55 patients. On-site, and two blinded off-site assessments were performed for unenhanced and contrast echocardiography, cineventriculography, and MRI according to pre-defined standards. Intra-class correlation coefficients (ICCs) were determined to assess inter-observer reliability between all three readers (i.e. one on-site and two off-site). EF was 56.2 +/- 18.3% by cineventriculography, 54.1 +/- 12.9% by MRI, 50.9 +/- 15.3% by unenhanced echocardiography, and 54.6 +/- 16.8% by contrast echocardiography. Correlation on EF between cineventriculography and echocardiography increased from 0.72 with unenhanced echocardiography to 0.83 with contrast echocardiography (P < 0.05). Similarly, correlation on EF between MRI and echocardiography increased from 0.60 with unenhanced echocardiography to 0.77 with contrast echocardiography (P < 0.05). The inter-observer reliability ICC was 0.91 (95% CI 0.88-0.94) in contrast echocardiography, followed by cardiac MRI (0.86; 95% CI 0.80-0.92), cineventriculography (0.80; 95% CI 0.74-0.85), and unenhanced echocardiography (0.79; 95% CI 0.74-0.85). CONCLUSIONS Unenhanced echocardiography resulted in slight underestimation of EF and only moderate correlation compared with cineventriculography and MRI. Contrast echocardiography resulted in more accurate EF and significantly improved correlation with cineventriculography and MRI. Contrast echocardiography significantly improved inter-observer agreement on EF compared with unenhanced echocardiography. Inter-observer reliability on EF using contrast echocardiography reaches a level comparable to MRI and is better than those obtained by cineventriculography.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dysglycemia and cardiovascular risk.

1. Hoffmann R, von Bardeleben S, Kasprzak JD, et al. Analysis of regional left ventricular function by cineventriculography, cardiac magnetic resonance imaging, and unenhanced and contrast-enhanced echocardiography: a multicenter comparison of methods. J Am Coll Cardiol 2006; 47:121–8. 2. Hoffmann R, von Bardeleben S, ten Cate F, et al. Assessment of systolic left ventricular function: a multi-...

متن کامل

Analysis of regional left ventricular function by cineventriculography, cardiac magnetic resonance imaging, and unenhanced and contrast-enhanced echocardiography: a multicenter comparison of methods.

OBJECTIVES To define the use of cineventriculography, cardiac magnetic resonance imaging (cMRI), and unenhanced and contrast-enhanced echocardiography for detection of left ventricular (LV) regional wall motion abnormalities (RWMA). BACKGROUND Detection of RWMA is integral to the evaluation of LV function. METHODS In 100 patients, cineventriculography and unenhanced and contrast-enhanced ec...

متن کامل

Analysis of left ventricular volumes and function: a multicenter comparison of cardiac magnetic resonance imaging, cine ventriculography, and unenhanced and contrast-enhanced two-dimensional and three-dimensional echocardiography.

BACKGROUND Contrast echocardiography improves accuracy and reduces interreader variability on left ventricular (LV) functional analyses in the setting of two-dimensional (2D) echocardiography. The need for contrast imaging using three-dimensional (3D) echocardiography is less defined. The aim of this multicenter study was to define the accuracy and interreader agreement of unenhanced and contra...

متن کامل

Should contrast be routinely used for echocardiographic assessment of left ventricular function? A matter of appropriateness.

Hoffmann et al. present data showing that contrastenhanced echocardiography, compared with unenhanced echocardiography, provides more accurate determination of left ventricular ejection fraction and significantly improves the correlation with cineventriculography and magnetic resonance imaging (MRI). Certainly, the most important question arising from this study is whether contrast injection sh...

متن کامل

The Correlation between Left and Right Ventricular Ejection Fractions in Patients with Ischemic Heart Disease, Documented by Cardiac Magnetic Resonance Imaging

Introduction: The correlation between right and left ventricular ejection fractions (RVEF and LVEF, respectively) has been studied in only a small number of patients with a marked decrease in RVEF and LVEF. The aim of the present study was to compare LVEF and RVEF in patients with ischemic heart disease. RVEF and LVEF were measured by Cardiovascular Magnetic Resonance (CMR) imaging. Materials a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European heart journal

دوره 26 6  شماره 

صفحات  -

تاریخ انتشار 2005