Rapid enantioseparation of 1-aminoindan by microchip electrophoresis with linear-imaging UV detection.

نویسندگان

  • Fumihiko Kitagawa
  • Shiori Aizawa
  • Koji Otsuka
چکیده

Chiral separations of 1-aminoindan (AI) by cyclodextrin electrokinetic chromatography (CDEKC) were investigated on microfluidic quartz chips. By using a microchip electrophoresis (MCE) instrument equipped with a linear-imaging UV detector, the separation process of the enantiomeric compounds was observed. When sulfated beta-cyclodextrin was employed as a chiral selector, the baseline separation of AI could be achieved within 1 min with a high repeatability. The relative standard deviation of the migration time was less than 6%. The fastest separation was achieved in 14 s, utilizing a separation length of only 6.1 mm. These results show that the MCE analysis employing a linear imaging UV detector has a significant potential for fast chiral analysis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Convenient enantioseparation by monolithic imprinted capillary clamped in a chip with electrochemical detection.

A microchip integrated with a monolithic imprinted capillary has been manufactured for performing the chip-based capillary electrochromatographic enantioseparation. The microporous monolith anchored on the inner wall of the microchannel was prepared by in situ chemical copolymerization, and characterized with scanning electron microscopy, IR spectroscopy, and solid-state UV-vis spectroscopy. Th...

متن کامل

High-speed analysis of proteins by microchip isoelectric focusing with linear-imaging UV detection.

High-speed analyses of proteins by microchip isoelectric focusing (MCIEF) were investigated on straight channel chips. By employing a commercially available microchip electrophoresis instrument equipped with a linear-imaging UV detector, sample proteins focused in a separation channel could be detected without a mobilization step. Typically, standard proteins were focused within 210 s at differ...

متن کامل

Enantioseparation and amperometric detection of chiral compounds by in situ molecular imprinting on the microchannel wall.

The molecular imprinting technique was first introduced into the microchannel of a microfluidic device to form in situ the imprinted polymer for fast enantioseparation of chiral compounds. The molecularly imprinted polymer (MIP) was in situ chemically polymerized on the microchannel wall using acrylamide as the functional monomer and ethylene glycol dimethacrylate as the cross-linker, and chara...

متن کامل

High-speed Enantioseparation by Microchip Electrophoresis

Microchip electrophoresis (MCE) has been recognized as an important separation technique on the research field of micro total analytical systems (μ-TAS) since the first publication on MCE was reported by Manz et al. in 1992 [1]. In MCE, there are several advantages, e.g., high speed analysis in seconds, small amount of sample, high separation efficiency, and high-throughput analysis by using mi...

متن کامل

Automatic Protein Separation by Microchip Electrophoresis Using Quartz Chip

Electrophoretic separation techniques using microchips have been dramatically improved and several commercial MCE systems have been developed. For example, the Agilent Technologies 2100 Bioanalyzer system is commercially available with a protein separation chip and reagent kit that enables rapid and highly efficient protein separation based on their molecular size [1]. Separation of protein mix...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical sciences : the international journal of the Japan Society for Analytical Chemistry

دوره 21 1  شماره 

صفحات  -

تاریخ انتشار 2005