Management of the Stiff Total Knee Arthroplasty with Revision to a Total Condylar Bearing Rotating Platform Prosthesis
ثبت نشده
چکیده
Total knee arthroplasty (TKA) is performed to relieve pain and restore function in patients with arthritic knees. There are approximately 700,000 knee replacements performed each year, and this number is projected to reach 3.5 million per year by 2030 [1]. Although knee replacements offer significant improvements in quality of life, they are not without complications. Stiffness is a known complication that occurs in 1.3-12% [2-4] of primary total knee arthroplasties. Stiffness is defined as having a flexion contracture of 10-15 degrees or a total arc of motion that is less than 90 degrees [5,6].
منابع مشابه
Cementless meniscal bearing knee arthroplasty: 7- to 12-year outcome analysis.
1. Rotational mobility of a widely used rotating platform total knee replacement. Iowa Orthop J, 2001. 21: p. 90. 2. Multi-contact-surface finite element model of a widely used rotating platform total knee. Polyethylene wear in meniscal knee replacement. A one to nine-year retrieval analysis of the Oxford knee.Unicompartmental "Lotus" knee prosthesis. Analysis of the results of a series of 142 ...
متن کاملDoes mobile-bearing knee arthroplasty motion change with activity?
BACKGROUND The purpose of this study was to evaluate the effect of mobile-bearing implant design and activity on knee arthroplasty kinematics during three activities of daily living. METHODS In vivo kinematics were analyzed using 3D model registration from fluoroscopic images of non-weightbearing knee flexion-extension, weight-bearing squatting and stair activities in 20 knees in 10 patients ...
متن کاملFrontal plane kinematics after mobile-bearing total knee arthroplasty.
Frontal plane kinematics including condylar lift-off and medial to lateral translation were investigated in 10 patients who had total knee arthroplasty with a mobile-bearing rotating platform or a similar implant that had been modified with a posterior stabilizer. The rotating platform had condylar lift-off (average, 2 mm) and medial tibial translation (average, 4.3 mm) in all implants tested. ...
متن کاملPosterior cruciate-retaining, rotating-platform total knee arthroplasty: minimum 4-year follow-up study.
Rotating-platform, mobile-bearing total knee arthroplasty was initially developed using a posterior cruciate-sacrificing technique and design. Posterior cruciate-substituting and -retaining, rotating-platform total knee arthroplasty designs were developed later. The purpose of this study was to evaluate a minimum 4-year follow-up of total knee arthroplasty performed with a posterior cruciate-re...
متن کاملRevision Total Knee Arthroplasty Using the Modern Constrained Condylar Knee Prosthesis
OBJECTIVE To determine whether the second-generation constrained condylar prosthesis provided satisfactory results in revision total knee arthroplasty. METHODS A series of 41 cases of revision total knee arthroplasty using the second-generation constrained condylar knee prosthesis was reviewed. The series comprised 7 men and 34 women with a mean age of 73.2 years. The original diagnosis was p...
متن کامل