Anatomic Total Talar Prosthesis Replacement Surgery and Ankle Arthroplasty: An Early Case Series in Thailand
نویسنده
چکیده
Little is known about specific outcomes and early experiences of total talar prosthesis replacement surgery in the current literature, and ankle arthroplasty in Southeast Asia. This study reported on four patients with talar loss or ankle arthritis. Patients were treated with a custom total talar prosthesis (anatomic-metallic version) replacement (TPR, n=1) or with total ankle replacement (TAR, n=3). Baseline data, including Visual-Analog-Scale Foot and Ankle (VAS-FA) and Quality of Life scores via Short-Form-36 (SF-36), were collected for all patients. Mean follow-up time was 7.6 months. From preoperative to postoperative, VAS-FA score increased from 6.0 to 57.5, and SF-36 score increased from 19.3 to 73.7 in a patient with TPR. Mean VAS-FA scores increased from 51.5±15.6 to 85.7±4.7 (P=0.032), and mean SF-36 scores tended to increase from 65.2±13.3 to 99.3±1.2 (P=0.055) in TAR group. This study is the first report of anatomic-metallic TPR which appears to provide satisfactory outcomes for treatment of talar loss at a short-term follow-up. TAR also provides acceptable results for treatment of ankle arthritis at this point.
منابع مشابه
Custom-Made Alumina Ceramic Total Talar Prosthesis for Idiopathic Aseptic Necrosis of the Talus: Report of Two Cases
Two women aged 65 years and 78 years presented to our center with idiopathic necrosis of the talus. In both cases, imaging examinations showed collapse and sclerotic changes of the talar body caused by the necrosis. Both women underwent resection and placement of a third-generation custom-made alumina ceramic total talar prosthesis. Immobilization of the ankle in a short-leg cast for 3 weeks wa...
متن کاملThe revolution and unanswered questions: commentary on an article by Beat Hintermann, MD, et al.: "HINTEGRA revision arthroplasty for failed total ankle prostheses".
BACKGROUND When a total ankle replacement fails, arthrodesis has been advocated as the treatment of choice. With the availability of a wide spectrum of implants, revision arthroplasty may become a viable alternative. METHODS We reviewed a consecutive series of 117 cases (116 patients [fifty-six female and sixty male]; mean age, 55.0 ± 12.0 years) in which a total ankle arthroplasty failed aft...
متن کاملAccuracy assessment of measuring component position after total ankle arthroplasty using a conventional method
BACKGROUND This study was to assess the accuracy of measuring the tibial and talar components position and to investigate the outlier rate of each component and predisposing factors related to component malalignment after total ankle arthroplasty (TAA) using a conventional method. METHODS One hundred fifty consecutive primary total ankle arthroplasty were performed using the three-component H...
متن کاملThe effect of accuracy of implantation on range of movement of the Scandinavian Total Ankle Replacement.
When performing the Scandinavian Total Ankle Replacement (STAR), the positioning of the talar component and the selection of mobile-bearing thickness are critical. A biomechanical experiment was undertaken to establish the effects of these variables on the range of movement (ROM) of the ankle. Six cadaver ankles containing a specially-modified STAR prosthesis were subjected to ROM determination...
متن کاملTotal ankle replacement. Early experiences with STAR prosthesis.
Early designs of Total Ankle Replacement (TAR) had a high failure rate. More recent experience with the 3-piece, meniscal bearing, total ankle replacement has been more promising. We report a review of the early results of our first 22 prostheses in 20 patients undergoing Scandinavian Total Ankle Replacement (STAR) in Northern Ireland. There was a mean follow-up time of 26 months. Seventeen pat...
متن کامل