Prospective study found that peripheral lymph node sampling reduced the false-negative rate of sentinel lymph node biopsy for breast cancer.

نویسندگان

  • Chao Han
  • Ben Yang
  • Wen-Shu Zuo
  • Yan-Song Liu
  • Gang Zheng
  • Li Yang
  • Mei-Zhu Zheng
چکیده

BACKGROUND Although sentinel lymph node biopsy (SLNB) can accurately predict the status of axillary lymph node (ALN) metastasis, the high false-negative rate (FNR) of SLNB is still the main obstacle for the treatment of patients who receive SLNB instead of ALN dissection (ALND). The purpose of this study was to evaluate the clinical significance of SLNB combined with peripheral lymph node (PLN) sampling for reducing the FNR for breast cancer and to discuss the effect of "skip metastasis" on the FNR of SLNB. METHODS At Shandong Cancer Hospital Affiliated to Shandong University between March 1, 2012 and June 30, 2015, the sentinel lymph nodes (SLNs) of 596 patients with breast cancer were examined using radiocolloids with blue dye tracer. First, the SLNs were removed; then, the area surrounding the original SLNs was selected, and the visible lymph nodes in a field of 3-5 cm in diameter around the center (i.e., PLNs) were removed, avoiding damage to the structure of the breast. Finally, ALND was performed. The SLNs, PLNs, and remaining ALNs underwent pathologic examination, and the relationship between them was analyzed. RESULTS The identification rate of SLNs in the 596 patients was 95.1% (567/596); the metastasis rate of ALNs was 33.7% (191/567); the FNR of pure SLNB was 9.9% (19/191); and after the SLNs and PLNs were eliminated, the FNR was 4.2% (8/191), which was significantly decreased compared with the FNR before removal of PLNs (P = 0.028). According to the detected number (N) of SLNs, the patients were divided into four groups of N = 1, 2, 3, and ≥4; the FNR in these groups was 19.6, 9.8, 7.3, and 2.3%, respectively. For the patients with ≤2 or ≤3 detected SLNs, the FNR after removal of PLNs was significantly decreased compared with that before removal of PLNs (N ≤ 2: 14.0% vs. 4.7%, P = 0.019; N ≤ 3: 12.2% vs. 4.7%, P = 0.021), whereas for patients with ≥4 detected SLNs, the decrease in FNR was not statistically significant (P = 1.000). In the entire cohorts, the "skip metastasis" rate was 2.5% (15/596); the FNR caused by "skip metastasis" was 2.1% (4/191). CONCLUSIONS The FNR of SLNB was associated with the number of SLNs. For patients with ≤3 detected SLNs, PLN sampling can reduce the FNR of SLNB to an acceptable level of less than 5%. Because of the existence of the "skip metastasis" and distinct metastasis patterns, the FNR of SLNB cannot be completely eliminated.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Feasibility of sentinel lymph node mapping in renal cell carcinoma using intraoperative radiotracer injection

Introduction: The applicability of sentinel lymph node biopsy for early detection of metastasis in patients with renal cell carcinoma (RCC) is still in the validation phase and under investigation, which might be due to the unpredictability of the lymphatic pattern in RCC. In this study, we aimed to evaluate the feasibility and accuracy of sentinel node biopsy in patients with ...

متن کامل

The need for skin pen marking for sentinel lymph node biopsy: A comparative study

  Introduction: There is a consensus in the literature that sentinel lymph node biopsy is the standard procedure for axillary staging in early stage (I and II) breast cancer patients. Usually during lymphoscintigraphy, the location of the sentinel lymph node is marked on the skin by an indelible ink. In this study we evaluated this issue in our patients. Methods: 40 ...

متن کامل

Relationship between Non-Technical Factors and Diagnostic Accuracy of Frozen Section in Axillary Lymph Nodes in Patients with Breast Cancer

Background and purpose: Regional lymph node involvement is one of the main prognostic factors for breast cancer. Intraoperative assessment of sentinel lymph node biopsy (SLNB) by frozen section (FS) allows necessary axillary lymph node dissection (ALND) at the same time. But, false negative results are the main problems of the FS. The aim of this study was to investigate the relationship betwee...

متن کامل

Sentinel Node Mapping in Non-small Cell Lung Cancer Using an Intraoperative Radiotracer Technique

 Objective(s): Lymph node metastases are the most significant prognostic factor in localized non-small cell lung cancer (NSCLC). Identification of the first nodal drainage site (sentinel node) may improve detection of metastatic nodes. Extended surgeries, such as lobectomy or pneumonectomy with lymph node dissection, are among the therapeutic options of higher acceptab...

متن کامل

Prediction Axillary Lymph Node Involvement Status on Breast Cancer Data

Introduction: one of the foremost usual methods for evaluating breast cancer is the removal of axillary lymph nodes (ALN) which include complications such as edema, limited hand movements, and lymph accumulation. Although studies have shown that the sentinel gland condition represents the axillary nodules context in the mammary gland, the efficacy, and safety of the guard node biopsy need to be...

متن کامل

Sentinel-lymph-node biopsy in patients with breast cancer before and after neoadjuvant chemotherapy (SENTINA): a prospective, multicentre cohort study.

BACKGROUND The optimum timing of sentinel-lymph-node biopsy for breast cancer patients treated with neoadjuvant chemotherapy is uncertain. The SENTINA (SENTinel NeoAdjuvant) study was designed to evaluate a specific algorithm for timing of a standardised sentinel-lymph-node biopsy procedure in patients who undergo neoadjuvant chemotherapy. METHODS SENTINA is a four-arm, prospective, multicent...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Chinese journal of cancer

دوره 35  شماره 

صفحات  -

تاریخ انتشار 2016