Bond of Reinforcement in High-Strength Concrete

نویسندگان

  • Joseph Jones
  • Julio A. Ramirez
چکیده

This paper describes an examination of the development of tension lap splices in high-strength concrete and the applicability of the restriction in the ACI 318 code where the values of √fc′ used to calculate development length shall not exceed 100 psi. The focus is on the development of splices with Grade 60 epoxy-coated and uncoated bars in normalweight concrete. A summary of the behavior of bond is presented to provide context for the study. It is followed by a literature review to analyze the relevant previous experimental work in this area. Based on the analysis of those data, a modification to the current code limitation is proposed. The main conclusion of this paper is that the limit of 100 psi (0.689 MPa) on the square root of the specified compressive strength in Section 12.1.2 of ACI 318-11 (Section 25.4.1.4 of 318-14) may be extended to 120 psi (0.827 MPa) based on the analysis of available data without significant modifications to the current provisions for concrete strengths up to 16,000 psi (110 MPa).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Influence of Nano-silica and Polypropylene Fibers on Bond Strength of Reinforcement and Structural Lightweight Concrete (RESEARCH NOTE)

In this study, first by surveythe parameters affecting the compressive strength, such as water to cement ratio, cementgrade, silica fume to cement percentage, and the various ratios oflight weight aggregate LECA, to total aggregate, Taguchi method is used, to test 9 mix designsobtained the mix design optimization. Since lightweight concrete is brittle like normal concrete, to resolve this probl...

متن کامل

Effect of the Concrete Strength on the Concrete-Steel Bond in Concrete Filled Steel Tubes

In this study, the concrete-steel bond strength of concrete filled cylindrical steel tubes has been experimentally investigated. 22 short, high strength and normal concrete filled circular steel tubes were tested. Push-out test was carried out as the common method to evaluate the bond carrying capacity. Four different concrete mixes were used in preparing the specimens. The steel tubes were w...

متن کامل

Effect of Impressed Current on Bond Strength Between Steel Rebar and Concrete

The deterioration of bond strength between reinforcing steel and concrete as a result of impressed cathodic current with respect to the exposure time was investigated. A current in the magnitude of 3ma/ft2 (based on reinforcing rebar area) was used for a period of five years. Chemical analyses for sodium (Na+), potassium (K+) and chloride (Cl-) ions in concrete cylinders were performed as a fun...

متن کامل

بررسی تأثیر محصورشدگی بتن در رفتار غیرخطی دیوارهای برشی بتن‌آرمه بالدار

Flanged shear walls are used extensively in moderate- and high-rise buildings to resist lateral loads induced by earthquakes. The seismic performance of many buildings is, therefore, closely linked to the behavior of the reinforced concrete walls. They must be carefully designed to provide not only adequate strength, but also sufficient ductility to avoid brittle failure under strong lateral lo...

متن کامل

Calibration of Bar-Concrete Bond Stress Relationships for Bond Stress Prediction of GFRP Soil Nails Using Experimental Pullout Tests

Even though steel bar is a conventional reinforcement in soil stabilization systems, the problem of corrosion of steel may lead to vast damages especially in aggressive environments. In the past decades, Fiber Reinforced Polymer (FRP) materials have offered an effective solution to overcome the corrosion problem. Despite numerous bond stress-displacement models for reinforcements in concrete, t...

متن کامل

Bond Strength of Hot – Dip Galvanized Reinforcement (b500b) with Concrete

P. Pokorný, D. Dobiáš, M. Vokáč – Czech Technical University – Klokner Institute, Prague, Czech Republic This paper evaluates the effect of initial corrosion damage to the surface of the hot dip galvanized steel coating in fresh concrete on its final bond strength. The tests were performed on uncoated and hot-dip galvanized ribbed reinforcements. The measurement of bond stress (τm) according to...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016