Relative occurrence of flow limitation and snoring during continuous positive airway pressure titration.
نویسندگان
چکیده
OBJECTIVES To examine the relative temporal appearance of flow limitation and snoring during continuous positive airway pressure (CPAP) titration, compare their sensitivity as indicators of airway obstruction, and assess their relative utility as feedback variables for automatic titration of CPAP. DESIGN Retrospective review of data. SETTING University teaching hospital. PATIENTS Fifty-three patients diagnosed as having obstructive sleep apnea or upper airway resistance syndrome undergoing CPAP titration. MEASUREMENTS AND RESULTS We used a prototype automatic CPAP device that adjusts pressure in response to apnea, snoring, and/or flow limitation. The present study takes advantage of the frequent automatic decreases in pressure from a therapeutic level, as well as any technician-initiated decreases in pressure. We tabulated, for each pressure decrease of >0.4 cm H2O, the occurrences of snoring alone, flow limitation alone, or simultaneous appearance of both. Of 2,177 automatic pressure decreases, 64% resulted in flow limitation alone, 8% in snoring alone, and 22% in the simultaneous occurrence of both. Overall, 86% of decreases resulted in flow limitation alone or were simultaneous with snoring, whereas 30% of decreases resulted in snoring alone or were simultaneous with flow limitation. In 10 of 35 patients, snoring alone occurred in > 10% of the pressure decreases. In all but 5 of 133 manual pressure decreases, flow limitation developed at or above the pressure at which snoring developed. CONCLUSIONS While detection of snoring occasionally provided additional information, overall flow limitation was the earliest indicator of obstruction during decreases in CPAP.
منابع مشابه
Automatic nasal continuous positive airway pressure titration in the laboratory: patient outcomes.
BACKGROUND Manual titration of nasal continuous positive airway pressure (NCPAP) treatment for obstructive sleep apnoea (OSA) is time consuming and expensive. There are now "intelligent" NCPAP machines that try to find the ideal pressure for a patient by monitoring a combination of apnoeas, hypopnoeas, inspiratory flow limitation, and snoring. Although these machines usually find similar pressu...
متن کاملVariability of inspiratory conductance quantifies flow limitation.
In the present study, our aim was to investigate whether the variability of conductance over the course of inspiration reflects flow limitation. Pressure/flow conditions in the upper airway were modelled by a collapsible tube within a rigid chamber and a pump simulating respiration. Instantaneous conductance was estimated every 20 ms as flow/resistive pressure, and its variability during inspir...
متن کاملInfluence of correction of flow limitation on continuous positive airway pressure efficiency in sleep apnoea/hypopnoea syndrome.
We evaluated the efficiency of two different treatment procedures with continuous positive airway pressure (CPAP) on sleep, nocturnal breathing characteristics and daytime vigilance in 18 newly diagnosed patients with untreated sleep apnoea/hypopnoea syndrome (SAHS) randomly allocated to two different groups. In group I, the positive pressure (PP) level was set to suppress flow limitation (PFL)...
متن کاملInteraction of cross-sectional area, driving pressure, and airflow of passive velopharynx.
Previous studies have shown that, when the pharyngeal muscles are relaxed, the velopharynx is a highly compliant segment of the pharynx. Thus, under these circumstances, cross-sectional area of the velopharynx (AVP), driving pressure across the velopharynx (DeltaP), and inspiratory airflow (VI) will be mutually interdependent variables. The purpose of the present investigation was to describe t...
متن کاملCPAP titration by an auto-CPAP device based on snoring detection: a clinical trial and economic considerations.
This study aimed to assess the ability of an auto-nasal continuous positive airway pressure (nCPAP) device (REM + auto; NPBFD, Nancy, France) to predict the optimal constant nCPAP level. The apnoea/hypopnoea detection facility of the auto-nCPAP device was deliberately disabled and nasal mask pressure vibration detection was the only mode of pressure setting. The auto-nCPAP device was tested on ...