Biomechanical comparison of bicortical versus unicortical screw placement of proximal tibia locking plates: a cadaveric model.

نویسندگان

  • Paul J Dougherty
  • Do-Gyoon Kim
  • Steve Meisterling
  • Christopher Wybo
  • Yener Yeni
چکیده

OBJECTIVE The purpose of this study was to compare the biomechanical properties of bicortical with unicortical screws in a proximal tibial fracture cadaveric model. SETTING Biomechanics laboratory at a Level 1 trauma center. PATIENTS/PARTICIPANTS Eight pairs (4 male and 4 female) of elderly (average age, 79 years; range, 63 to 104 years) cadaveric tibiae. INTERVENTION Osteotomies were performed in the proximal tibia to reproduce a 41-C2 bicondylar fracture pattern. The 4.5-mm proximal tibial periarticular locking plates (Smith-Nephew, Memphis, TN) were applied to the tibiae with 4 proximal bicortical or unicortical locking screws and 3 screws distal to the fracture site. The fixed tibiae were tested by using a materials testing machine (Instron, Canton, MA) with the axial load on the medial condyle. OUTCOME MEASUREMENTS The bicortical and unicortical constructs were compared for stiffness, yield load and displacement, and maximum load and displacement to failure. RESULTS : Bicortical screw placement significantly outperformed unicortical screw placement in stiffness (53.1 +/- 6.7 N/mm versus 35.6 +/- 7.2 N/mm, P < 0.002) and maximum load (476.5 +/- 83.8 N versus 258.9 +/- 62.1 N, P < 0.001) but the yield properties and the ultimate displacement were not significantly different. CONCLUSION Bicortical screw placement may provide a biomechanically superior construct than unicortical screw placement for the stabilization of unstable proximal tibia fractures.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Biomechanical Comparison of Bicortical, Unicortical, and Unicortical Far-Cortex-Abutting Screw Fixations in Plated Comminuted Midshaft Clavicle Fractures.

PURPOSE The objective of this study was to assess the biomechanical properties of bicortical locking screws, unicortical locking screws, and unicortical far-cortex-abutting locking screw fixation in a cadaver model of comminuted midshaft clavicle fractures stabilized with a locking plate placed on the superior surface of the clavicle. METHODS Nine pairs of adult fresh-frozen cadaver clavicles...

متن کامل

Unicortical versus bicortical locked plate fixation in midshaft clavicle fractures.

Higher rates of poor outcomes in displaced midshaft clavicle fractures treated nonoperatively have recently been reported. Along with expanding indications for operative fixation and increasing application of locked plate constructs, it is unknown whether complications related to bicortical penetration of the clavicle can be avoided using unicortical fixation. The purpose of this study is to co...

متن کامل

A biomechanical study comparing plate fixation using unicortical and bicortical screws in transverse metacarpal fracture models subjected to cyclic loading.

The use of bicortical screws to fix metacarpal fractures has been suggested to provide no added biomechanical advantage over unicortical screw fixation. However, this was only demonstrated in static loading regimes, which may not be representative of biological conditions. The present study was done to determine whether similar outcomes are obtained when cyclic loading is applied. Transverse mi...

متن کامل

Biomechanical comparison of a locking compression plate combined with an intramedullary pin or a polyetheretherketone rod in a cadaveric canine tibia gap model.

OBJECTIVE To compare the biomechanical properties of a 10-hole 3.5 mm locking compression plate (LCP) with 2 proximal and 2 distal bicortical locked screws reinforced with either a Steinmann pin of 30-40% the medullary diameter or a poly-ether-ether-ketone (PEEK) rod of ∼75% the medullary diameter in a cadaveric tibia gap model. STUDY DESIGN Ex vivo study. SAMPLE POPULATION Cadaveric canine...

متن کامل

Medial malleolar fractures: a biomechanical study of fixation techniques.

Fracture fixation of the medial malleolus in rotationally unstable ankle fractures typically results in healing with current fixation methods. However, when failure occurs, pullout of the screws from tension, compression, and rotational forces is predictable. We sought to biomechanically test a relatively new technique of bicortical screw fixation for medial malleoli fractures. Also, the AO gro...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of orthopaedic trauma

دوره 22 6  شماره 

صفحات  -

تاریخ انتشار 2008