Steady-state end-tidal alveolar dead space fraction and D-dimer: bedside tests to exclude pulmonary embolism.

نویسندگان

  • M A Rodger
  • G Jones
  • P Rasuli
  • F Raymond
  • H Djunaedi
  • C N Bredeson
  • P S Wells
چکیده

STUDY OBJECTIVE Less than 35% of patients suspected of having pulmonary embolism (PE) actually have PE. Safe bedside methods to exclude PE could save health-care resources and improve access to diagnostic testing for suspected PE. In patients with suspected PE, we sought to determine the sensitivity, specificity, and negative predictive value of (1) a steady-state end-tidal alveolar dead space fraction (AVDSf) of < 0.15, (2) a negative D-dimer result, and (3) the combination of a steady-state end-tidal AVDSf of < 0.15 and a negative D-dimer result. STUDY DESIGN Prospective cohort study. SETTING Tertiary-care center in Ottawa, Ontario, Canada. PATIENTS Consecutive inpatients, outpatients, and emergency department patients with suspected PE referred to the Departments of Nuclear Medicine or Radiology for investigation of suspected PE. INTERVENTIONS AND MEASUREMENTS All study patients had D-Dimer and alveolar dead space measurements prior to determining outcome (PE or no PE) with ventilation/perfusion scans and/or noninvasive leg vein imaging and/or pulmonary angiography. RESULTS Two hundred forty-six eligible and consenting patients underwent diagnostic imaging that excluded PE in 163 patients, diagnosed PE in 49 patients, and was indeterminant in 34 patients. A negative D-dimer result excluded PE with a sensitivity of 83.0% (95% confidence interval [CI], 69.2 to 92.4%), a negative predictive value of 91.2% (95% CI, 83.4 to 96.1%), and a specificity of 57.6%. A steady-state end-tidal AVDSf of < 0.15 excluded PE with a sensitivity of 79.5% (95% CI, 63.5 to 90.7%), a negative predictive value of 90.7% (95% CI, 82.5 to 95.9%), and a specificity of 70.3%. The combination of a negative D-dimer result and a steady-state end-tidal AVDSf of < 0.15 excluded PE with a sensitivity of 97.8% (95% CI, 88.5 to 99.9%), a negative predictive value of 98.0% (95% CI, 89.4 to 99.9%), and a specificity of 38.0%. CONCLUSION This simple combination of bedside tests may safely rule out PE without further diagnostic testing in large numbers of patients with suspected PE.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Diagnostic Value of End-tidal Carbon Dioxide (EtCO2) and Alveolar Dead Space (AVDS) in Patients with Suspected Pulmonary Thrombo-embolism (PTE)

Introduction: Capnography, is an easy, fast and practical method which its application in the diagnosis of Pulmonary Thromboendarterectomy (PTE) has recently been studied. This study aimed to assess the diagnostic value of end-tidal CO2 (ETCO2) and the alveolar dead space (AVDS) in the diagnosis of patients suspected to PTE who have been referred to the emergency department. Materials and Metho...

متن کامل

The bedside investigation of pulmonary embolism diagnosis study: a double-blind randomized controlled trial comparing combinations of 3 bedside tests vs ventilation-perfusion scan for the initial investigation of suspected pulmonary embolism.

BACKGROUND We sought to determine whether using combinations of 3 bedside tests (7-variable clinical model, non-enzyme-linked immunosorbent assay D-dimer test, and alveolar dead-space fraction) to exclude pulmonary embolism (PE) before diagnostic imaging was as safe as a standard strategy of starting with ventilation-perfusion (V/Q) scan. METHODS In this double-blind, randomized, controlled e...

متن کامل

Volumetric capnography as a screening test for pulmonary embolism in the emergency department.

STUDY OBJECTIVE To compare the diagnostic performance of volumetric capnography (VCap), which is the plot of the expired CO(2) partial pressure against the expired volume during a single breath, with the PaCO(2) to end-tidal CO(2) (EtCO(2)) gradient, in the case of suspected pulmonary embolism (PE). DESIGN Single-center, prospective study. SETTING Emergency department of a teaching hospital...

متن کامل

Bedside end-tidal CO2 tension as a screening tool to exclude pulmonary embolism.

End tidal carbon dioxide tension (P(ET,CO(2))) is a surrogate for dead space ventilation which may be useful in the evaluation of pulmonary embolism (PE). We aimed to define the optimal P(ET,CO(2)) level to exclude PE in patients evaluated for possible thromboembolism. 298 patients were enrolled over 6 months at a single academic centre. P(ET,CO(2)) was measured within 24 h of contrast-enhanced...

متن کامل

Capnography as a diagnostic tool for pulmonary embolism: a meta-analysis.

STUDY OBJECTIVE Multiple studies have evaluated capnography for the diagnosis of pulmonary embolism; accordingly, we conduct a meta-analysis of these trials. METHODS We performed a systematic search from 1990 to 2011, using MEDLINE, EMBASE, and the Cochrane Library, including studies evaluating capnography as a diagnostic tool alone or in conjunction with other tests. After study quality eval...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Chest

دوره 120 1  شماره 

صفحات  -

تاریخ انتشار 2001